![Klein Tools CL2500 Instruction Manual Download Page 7](http://html.mh-extra.com/html/klein-tools/cl2500/cl2500_instruction-manual_1977242007.webp)
Overload Protection:
• Voltage:
600V RMS
• Current:
2000µA (leads), 1000A (clamp)
AC Current Measurement
Range
Resolution
Accuracy
600µA
0.1µA
± (2.0% + 5 digits)
2000µA
1µA
± (1.5% + 5 digits)
60A
0.01A
± (2.9% + 15 digits)
600A ~ 1000A
0.1A ~ 1A
± (1.9% + 8 digits)
Overload Protection:
• Voltage:
600V RMS
• Current:
2000µA (leads), 1000A (clamp)
Frequency:
45 to 400Hz
Minimum Current for Frequency Measurement:
400µA (leads) or 20A (clamp)
Response:
True RMS
Resistance Measurement
Range
Resolution
Accuracy
600
Ω
˜ 6M
Ω
0.1
Ω
˜ 0.001M
Ω
± (1.0% + 4 digits)
60M
Ω
0.01M
Ω
± (2.0% + 4 digits)
Overload Protection:
600V RMS
Capacitance Measurement
Range
Resolution
Accuracy
60nF ˜ 6000µF
0.01nF ˜ 1µF
± (3.5% + 6 digits)
Overload Protection:
600V RMS
Frequency Measurement
Range
Resolution
Accuracy
99.99Hz ˜ 499.9kHz
0.01Hz ˜ 100Hz
± (0.1% + 4 digits)
Overload Protection:
600V RMS
Duty Cycle Measurement
Range
Resolution
Accuracy
0.1 ˜ 99.9%
0.1%
± (0.2% per kHz + 0.1% + 5 digits)
Overload Protection:
600V RMS
Diode Test
Overload Protection
Range
Test Current
Open Circuit Voltage
600V RMS
6.0V
Appx. 0.25mA
< 1.8V DC
Continuity Test
Overload Protection
Open Circuit Voltage
Threshold (Appx.)
600V RMS
< 0.44V
~40
Ω
Non Contact Voltage Detector
On Voltage
Appx. 25V AC and above