Overload Protection: 

 

•  Voltage:

 600V RMS

•  Current: 

2000µA (leads), 1000A (clamp)

AC Current Measurement

Range

Resolution

Accuracy

600µA

0.1µA

± (2.0% + 5 digits)

2000µA

1µA

± (1.5% + 5 digits)

60A

0.01A

± (2.9% + 15 digits)

600A ~ 1000A

0.1A ~ 1A

± (1.9% + 8 digits)

Overload Protection:

  

•  Voltage:

 600V RMS

•  Current:

 2000µA (leads), 1000A (clamp)

Frequency:

 45 to 400Hz

Minimum Current for Frequency Measurement:

 400µA (leads) or 20A (clamp)

Response:

 True RMS

Resistance Measurement

Range

Resolution

Accuracy

600

Ω

 ˜ 6M

Ω

0.1

Ω

 ˜ 0.001M

Ω

 

± (1.0% + 4 digits)

60M

Ω

0.01M

Ω

± (2.0% + 4 digits)

Overload Protection:

 600V RMS

Capacitance Measurement

Range

Resolution

Accuracy

60nF ˜ 6000µF

0.01nF ˜ 1µF

± (3.5% + 6 digits)

Overload Protection: 

600V RMS

Frequency Measurement

Range

Resolution

Accuracy

99.99Hz ˜ 499.9kHz

0.01Hz ˜ 100Hz

± (0.1% + 4 digits)

Overload Protection:

 600V RMS

Duty Cycle Measurement

Range

Resolution

Accuracy

0.1 ˜ 99.9%

0.1%

± (0.2% per kHz + 0.1% + 5 digits)

Overload Protection:

 600V RMS

Diode Test

Overload Protection

Range

Test Current

Open Circuit Voltage

600V RMS

6.0V

Appx. 0.25mA

< 1.8V DC

Continuity Test

Overload Protection

Open Circuit Voltage

Threshold (Appx.)

600V RMS

< 0.44V

~40

Ω

Non Contact Voltage Detector

On Voltage

Appx. 25V AC and above

Summary of Contents for CL2500

Page 1: ...Instruction Manual F o r P r o f e s s i o n a l s S i n c e 1 8 5 7 CL2500 1000A AC DC TRUE RMS DC ZERO BACKLIGHT WORKLIGHT BAR GRAPH MAX MIN HOLD 3 5 6 DIGIT 5999 COUNT LCD AUTO MANUAL RANGE NON CO...

Page 2: ...eath Before each use verify meter operation by measuring a known voltage or current Never use the meter on a circuit with voltages that exceed the category based rating of this meter Do not use the me...

Page 3: ...ncy and Duty Cycle modes Zero the DC current clamp reading E Hold Backlight Worklight Press to hold the current input on the display Press again to return to live reading Press for 2 seconds to enable...

Page 4: ...han the digital display The scale of the bar graph is zero to the maximum reading of the selected range FUNCTION INSTRUCTIONS 7 1 6 2 3 5 1 AC DC Current large 1000A Features ZERO DC MAX MIN RANGE HOL...

Page 5: ...ve circuit 6 Capacitance 6000 F Features HOLD Safely discharge capacitor before measurement Reading may take up to 60 seconds for large capacitors 7 Diode Continuity Display shows Forward voltage drop...

Page 6: ...est Relative Zero Mode n Nano 10 9 Micro 10 6 m Milli 10 3 k Kilo 103 M Mega 106 ELECTRICAL SPECIFICATIONS DC Voltage Measurement Range Resolution Accuracy 600mV 600V 0 1mV 0 1V 0 5 4 digits 1000V 1V...

Page 7: ...0 4 digits 60M 0 01M 2 0 4 digits Overload Protection 600V RMS Capacitance Measurement Range Resolution Accuracy 60nF 6000 F 0 01nF 1 F 3 5 6 digits Overload Protection 600V RMS Frequency Measurement...

Page 8: ...s shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss Some...

Reviews: