![Klein Tools 092644693748 Instruction Manual Download Page 10](http://html.mh-extra.com/html/klein-tools/092644693748/092644693748_instruction-manual_1977328010.webp)
10
AC/DC CURRENT
NOTE:
The meter defaults to AC measurement. Press the "SEL"
button
10
to toggle between AC and DC modes. The AC or DC icon
on the LCD indicates which mode is selected.
1. Attach test leads to the appropriate jacks and rotate function
selector switch
2
to the appropriate setting as follows:
• For AC/DC currents >400mA and <10A:
Insert RED test lead into
10A jack
3
, and BLACK test lead into COM jack
4
, and rotate
function selector switch
2
to the 10A AC/DC setting.
ENGLISH
OPERATING INSTRUCTIONS
AC/DC VOLTAGE (LESS THAN 600V)
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into COM
jack
4
, and rotate function selector switch
2
to the V setting.
NOTE:
The meter defaults to AC measurement. Press the "SEL"
button
10
to toggle between AC and DC modes. The
AC
or
DC
icon
on the LCD indicates which mode is selected.
2. Apply test leads to the circuit to be tested to measure voltage.
The meter will auto-range to display the measurement in the
most appropriate range.
NOTE:
The hazardous voltage indicator will appear for voltages >30V.
NOTE:
If "
–
" appears on the LCD, the test leads are being applied
to the circuit in reverse polarity. Swap the position of the leads to
correct this.
NOTE:
When in a voltage setting and the test leads are open,
readings of order mV may appear on the display. This is noise and
is normal. By touching the test leads together to close the circuit
the meter will measure zero volts.
Red lead
Black lead
Red lead
Black lead
www.
GlobalTestSupply
.com
Find Quality Products Online at: