15
OPERATING INSTRUCTIONS
DIODE TEST
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Continuity/Resistance/Capacitance/Diode-Test
setting.
NOTE:
The meter defaults to Continuity testing in this mode.
Press the "SEL/NCV" button
12
repeatedly until the diode icon
appears on the display.
Touch test leads to diode. A reading of 200-800mV on display
indicates forward bias, "
OL
" indicates reverse bias. An open device
will show "
OL
" in both polarities. A shorted device will show
approximately 0mV.
µA DC CURENT (LESS THAN 200 µA)
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch
2
to the
DC μA setting. The "
μA
" and "
DC
" icons will appear on the display.
2. Remove power from circuit and open circuit at measurement point.
3. Connect test leads in series with the circuit.
4. Apply power to the circuit to take the measurement.
DO NOT attempt to measure more than 200µA.
Red lead
Black lead
Red lead
Black lead
www.calcert.com
1.800.544.2843
0
5
10
15
20
25
30