4
OTHER MEASUREMENT APPLICATIONS
Maximum Input:
600V DC or 600V AC RMS
•
Diode Test:
Approx. 1mA, open circuit voltage ~3.0V DC
•
Continuity Check:
Audible signal <10Ω, max current 1.5mA
•
Sampling Frequency:
3 samples per second
•
Auto Power off:
After ~15 minutes of inactivity.
•
Overload:
"OL" indicated on display
•
Polarity:
"-" on display indicates negative polarity
•
Display:
3-3/4 digit, 4000 Count LCD
ELECTRICAL SPECIFICATIONS
Function
Range
Resolution
Accuracy
Capacitance
40.00nF
0.010nF
±(4% + 25 digits)
400.0nF
0.100nF
±(4% + 8 digits)
4.000μF
0.001μF
40.00μF
0.010μF
400.0μF
0.100μF
4.000mF
0.001mF
±(10% + 9 digits)
Maximum Input:
600V AC RMS or 600V DC
Temperature
-40° to 1832°F
1°F
≤0°F ±(2.8% + 12 digits)
>0°F ±(2.8% + 6 digits)
-40° to 1000°C
1°C
±(2.8% + 6 digits)
Frequency
10Hz to
1MHz
0.001Hz
to 1kHz
±(0.1% + 5 digits)
Duty Cycle
0.1% to 99.9%
(≤100kHz)
0.01%
±1.5%
(Range: 10% – 90%)
Sensitivity:
250mV and < 20V RMS
Maximum Input:
600V AC or 600V DC RMS
ENGLISH
Summary of Contents for 09264469018