4-12
CHAPTER 4 Equipment Maintenance
MA-X View 600 Sonar System Operations and Maintenance Manual P/N 11210097, Rev. 00
4.3.4 Removing the
Side Scan
Transducers
To remove the side scan
transducers:
1.
Perform Steps 1 through 4
in “Disassembling the
Towfish” on page 4-3.
2.
Remove the skid plate as
described in “Removing the
Skid Plate” on page 4-11.
3.
Perform Steps 1 through 4
in “Removing the Gap-
filling Transducers” on
page 4-13.
4.
Using the 4-mm hex key, remove the eight socket head cap screws securing
the transducer assembly to the towfish housing.
5.
Carefully separate the
transducer assembly from
the towfish housing.
6.
Repeat Steps 3 and 4 to
remove the other side scan
transducer.
4.3.5 Installing the
Side Scan
Transducers
To install the side scan
transducers:
1.
Reverse Steps 2 through 4
in “Removing the Side
Scan Transducers” above
for each transducer.
2.
Slide the nose cone into the towfish housing, aligning the locator pin on the
nose cone with the slot in the housing and threading the nose cone retaining
bolt into the end cap as shown in Figure 4-14 on page 4-10.
3.
Tighten the nose cone retaining bolt.
Figure 4-17:
Removing the Eight Socket Head
Cap Screws Securing a Transducer Assembly
Figure 4-18:
Separating a Transducer
Assembly from the Towfish Housing
Summary of Contents for MA-X VIEW 600
Page 30: ......
Page 54: ......
Page 77: ...SP III TPU 5 7 Figure 5 3 SP III TPU Electronics Block Diagram...
Page 86: ......
Page 92: ......
Page 96: ......
Page 99: ...D 3...
Page 103: ...E 3...
Page 105: ...E 5...
Page 106: ......
Page 109: ...F 3...
Page 111: ...F 5...
Page 113: ...F 7...
Page 115: ...F 9...
Page 117: ...F 11...
Page 119: ...F 13...
Page 121: ...F 15...
Page 123: ...F 17...
Page 125: ...F 19...
Page 126: ......