Klein + Hummel M 50 Installation & Operation Manual Download Page 4

2. Installation

2.1. Power source

The amplifier electronics of the standard European model are
set up for an AC line voltage of 230 volts, 50 or 60 Hz. Export

versions with other
voltages are also
available. Additionally
operation from a 12 to
14 V DC source is
provided. The DC
connectors (6.35 mm flat
plugs) are hidden under
a plastic cover. A non
reversable plug case is
delivered with the
speaker. Be sure of the
correct polarity as shown
on the imprint. A
protection diode prevents
from damage caused by
wrong polarity.

2.2 Operating
conditions

The K+H model M 50 active control monitor is intended for
use over a range of ambient temperatures from +10° C to
+40° C (+50° F to +104° F). During transport or storage,
temperatures from -25° C to +70° C (-13° F to 158° F) are
permissible.

2.3. AF - Input

The sensitivity of the transformer-balanced floating input is
+6 dBu (1.55 volts rms). Changing an internal resistor results
in a sensivity of 0 dBu (0.775 volt rms). The three-pin female
XLR jack is wired in the standard manner (pin 1 = ground, pin
2 = +, pin 3 = -).

 

If you are connecting unbalanced analog

sources, you will need to solder a bridge between pins 1 and
3:

  unbalanced

balanced

as seen from the solder terminals of male XLR

Please observe, that the analog input level does not
exceed 7 volts rms.

2.4 Mains switch

The mains switch is located on the back of the speaker. A red
LED on the front side indicates the correct operation.

2.5 Volume control

The volume control is located on the front panel. The maximum
sensitivity of 1,55 V is achieved at full clockwise position.

2. Installation

2.1. Power source

The amplifier electronics of the standard European model are
set up for an AC line voltage of 230 volts, 50 or 60 Hz. Export

versions with other
voltages are also
available. Additionally
operation from a 12 to
14 V DC source is
provided. The DC
connectors (6.35 mm flat
plugs) are hidden under
a plastic cover. A non
reversable plug case is
delivered with the
speaker. Be sure of the
correct polarity as shown
on the imprint. A
protection diode prevents
from damage caused by
wrong polarity.

2.2 Operating
conditions

The K+H model M 50 active control monitor is intended for
use over a range of ambient temperatures from +10° C to
+40° C (+50° F to +104° F). During transport or storage,
temperatures from -25° C to +70° C (-13° F to 158° F) are
permissible.

2.3. AF - Input

The sensitivity of the transformer-balanced floating input is
+6 dBu (1.55 volts rms). Changing an internal resistor results
in a sensivity of 0 dBu (0.775 volt rms). The three-pin female
XLR jack is wired in the standard manner (pin 1 = ground, pin
2 = +, pin 3 = -).

 

If you are connecting unbalanced analog

sources, you will need to solder a bridge between pins 1 and
3:

  unbalanced

balanced

as seen from the solder terminals of male XLR

Please observe, that the analog input level does not
exceed 7 volts rms.

2.4 Mains switch

The mains switch is located on the back of the speaker. A red
LED on the front side indicates the correct operation.

2.5 Volume control

The volume control is located on the front panel. The maximum
sensitivity of 1,55 V is achieved at full clockwise position.

Summary of Contents for M 50

Page 1: ...9 0 711 45893 35 eMail info klein hummel de Internet www klein hummel de Active Control Monitor M 50 058 E0015 Version 01 2003 Installation Operation KLEIN HUMMEL GmbH Zeppelinstrasse12 73760Ostfildern Germany Tel 49 0 711 45893 0 Fax 49 0 711 45893 35 eMail info klein hummel de Internet www klein hummel de Active Control Monitor M 50 ...

Page 2: ...nsure that the operating voltage of the unit matches that of the local mains current AC line voltage 1 Safety Instructions It is absolutely essential that you read these safety instructions carefully before connecting and using this K H product Your safety depends on it Furthermore failure to follow these instructions voids the warranty To ensure safe operation for years to come keep these instruc...

Page 3: ...m power surges during an extended absence disconnect the power cable from the wall outlet Fig B Fig A Always check before connecting the power cable to the mains socket that the power switch on the unit itself is set to off O Use the power cable or power supply that came with the unit to connect to the mains socket wall outlet Power supply a damaged power cable may not be repaired Use a new cable ...

Page 4: ... located on the front panel The maximum sensitivity of 1 55 V is achieved at full clockwise position 2 Installation 2 1 Power source The amplifier electronics of the standard European model are set up for an AC line voltage of 230 volts 50 or 60 Hz Export versions with other voltages are also available Additionally operation from a 12 to 14 V DC source is provided The DC connectors 6 35 mm flat pl...

Page 5: ...ting of bass and treble by extern sound contols due to large monitoring distances or bad positioning 2 6 Mounting On the bottom there is a 3 8 threaded bushing for mounting the M 50 on a standard microphone tripod The LH 11 table mount bracket can be fixed to the two M6 threaded holes in the sides and so allows rotation around horizontal and verti kal axis 2 7 Mains and Battery Fuses The mains fus...

Page 6: ...y Proof of purchase date can be made by filing copies of appropriate documents invoice delivery note 3 3 Volume control The volume control on the front side can be set down to mi nus infinity 4 Warranty Information All K H products undergo an extensive procedure of quality control testing before leaving the factory Before semiconductors are mounted on the circuit board they are subject to rigorous...

Page 7: ...k brown latercharcoal grey RAL7021 others optional add on price Baffle cover fixed metal grille Specifications M 50 Free field frequency response 120 Hz 15 kHz 5 dB Self generated noise 10 cm 20 dB A Total harmonic distortion k2 and k3 above 350 Hz 1 80 dB SPL 1m Max sound pressure level in half space 3 THD 100 dB SPL averaged between 100 Hz and 6 kHz Electronics Amplifier power output Mains opera...

Page 8: ...y Tel 49 0 711 45893 0 Fax 49 0 711 45893 35 eMail info klein hummel de Internet www klein hummel de KLEIN HUMMEL GmbH Zeppelinstrasse12 73760Ostfildern Germany Tel 49 0 711 45893 0 Fax 49 0 711 45893 35 eMail info klein hummel de Internet www klein hummel de ...