Klein + Hummel 0300 D Installation And Operation Manual Download Page 2

Page 2

  Active Studio Monitor O 300 D

Safety Instructions

Safety Instructions

Safety Instructions

Safety Instructions

Safety Instructions

It is absolutely essential that you read these safety instructions carefully before connecting and using this K+H
product. Your safety depends on it. Furthermore, failure to follow these instructions voids the warranty.

 To ensure

safe operation for years to come, keep these instructions in a safe place for future reference. K+H has manufactured
this product in accordance with IEC 92 (SEC) 39 standards, then tested and delivered it in safe operating condition.
To maintain it in this condition, you must:

observe all safety instructions,

use the product only as described herein,

have any maintenance, repairs, or modifications performed only by K+H or other authorized personnel, and

ensure that the room in which you use this product is wired in accordance with the local electrical code.

Warning!

When the interior of the cabinet is exposed, touching some parts can lead to an electric shock.

If you need to gain access to the interior electronics of the unit, always disconnect the unit from any and all power
sources first.

Any repairs, maintenance, or other service of the unit when its interior compartment is exposed may only be
performed safely (in accordance with VBG 4) by authorized technicians familiar with all the risks involved. Even in
an unplugged state, a fully charged capacitor in the unit can zap the unsuspecting.

Loudspeaker output jacks labeled with the IEC 417/5036 emblem (Fig. A, right) may be carrying
dangerously high voltages. If your unit has this emblem, ensure that any connections to be
made between these jacks and the speakers themselves are made before powering up the
unit, and are done so only with manufacturer-approved interconnecting cables.

If you need to replace any fuses, ensure that the replacements are of exactly the same type,
value and voltage as the originals, as spelled out in the technical specifications at the rear of
this manual.

Do not use "repaired" fuses.

If you do not have any fuses on hand of the specified size, type, and value, do not hot-wire the
contacts in the holder by short-circuiting them.

Certain areas of the cabinet, cover, and rear panel can achieve extreme temperatures and are
therefore marked with a "HOT" label (Fig. B). Refrain from touching any heat sink or ventilation
grille.

High volume levels are known to cause permanent - i.e. irreversible - hearing damage, especially
when listened to without sufficient breaks. The higher the levels, the more frequent and exten-
ded must be the breaks. Avoid standing too close to loudspeakers that are being driven at high
levels. If you must be exposed to high sound pressure levels over an extended period of time,
use hearing protection.

Mains Connection:

This unit is designed for continuous operation.

Ensure that the operating voltage of the unit matches that of the local mains current (AC line voltage).

Always check before connecting the power cable to the mains socket that the power switch on the unit itself is set
to off ("O").

Use the power cable or power supply that came with the unit to connect to the mains socket (wall outlet).

Power supply: a damaged power cable may not be repaired. Use a new cable.

Avoid plugging the mains cable into a power strip that already has several other power-consuming devices
connected to it.

Avoid using extension cables. The unit must be connected to a mains socket close to it, and that socket should
be freely accessible.

Installation:

This product may only be placed on a stable, clean, horizontal surface.

Do not expose this product to vibration.

Do not operate this product anywhere near water or other liquids. Do not use it near a sink, swimming pool,
bathtub, or in any damp room or area. Electrical shocks carried through water can kill. Do not place any beverages
whatsoever on or near this product, as liquids can kill electronic components.

Ensure sufficient ventilation around the product to allow for adequate heat dissipation, especially near the rear
panel and the sides of the cabinet (minimum of 8 inches from the nearest wall). The unit may only be installed in
a rack if measures are taken to ensure sufficient ventilation and if the mounting instructions of the manufacturer
are followed. Do not block or cover any heat sink, fan, or vent.

Do not place the product where it will be in the path of direct sunlight, and keep it a safe distance away from
radiators and other heaters of any kind.

If you bring this product from a cold environment into a warm one (such as from a vehicle into a studio), it is quite
possible that condensation will form inside the cabinet. Please allow the unit sufficient time for acclimatisation
to room temperature (minimum thirty minutes) before connecting and powering up.

To avoid accidents, do not use any accessory equipment with this product which is not approved by the manufacturer,
particularly mounting accessories. Do not place this unit on any unstable platform, cart, stand or table. Should the
unit fall, it can cause bodily injury to persons, or can be damaged itself.

To protect this product from lightning damage during a thunderstorm or from power surges during an extended
absence, disconnect the power cable from the wall outlet.

Fig. A

Fig. B

Summary of Contents for 0300 D

Page 1: ...O300 D Active Studio Monitor Installation and Operation...

Page 2: ...the more frequent and exten ded must be the breaks Avoid standing too close to loudspeakers that are being driven at high levels If you must be exposed to high sound pressure levels over an extended p...

Page 3: ...itions 4 1 3 Speaker Placement 4 1 4 MAINS Connection 4 1 5 MAINS Switch 4 1 6 MAINS Fuse 4 1 7 Level Room Compensation Ground Lift 5 1 7 1 XLR Input 5 1 7 2 BNC Input 5 1 7 3 Level ATT ENUATOR 6 1 7...

Page 4: ...inet vertically with the tweeter and midrange dome at the top In certain applications where there are hard reflective surfaces immediately to the left or right of the speakers it may make more sense t...

Page 5: ...AL INPUT THROUGH This digital input configured as a 75 Ohm BNC connector is intended to receive signal sources in S P DIF or AES 3id format The incoming digital signal line requires one one one one o...

Page 6: ...ode right channel Position L Digital mode left channel Position M Digital mode mono summed from both left and right channels Simultaneous operation from one analog and one digital source is not possib...

Page 7: ...exception of the bass peak limiter For optimal power amp utilization even under varying voltage conditions and loads the peak limiter in the woofer channel was left in but the thermo limiter is deact...

Page 8: ...t to any extreme wear and tear Take care when handling the enamel coated cabinet not to damage the finish To clean the cabinet use a soft cloth with a mild cleaning agent only Under no circumstances s...

Page 9: ...deal for optimal dispersion with a mild horn shape around the mid range dome and an elliptical horn for the tweeter Thus came to be the dispersion pattern we mentioned earlier which is narrower vertic...

Page 10: ...original packing material and carton together with a detailed description of the problem and ship it freight prepaid to our distributor K H warrants that the product is free from any defects in both m...

Page 11: ...ifiers Bass amplifier 150 watts RMS THD 0 1 250 watts peak Midrange amplifier 65 watts RMS THD 0 1 75 watts peak Treble amplifier 65 watts RMS THD 0 1 110 watts peak Controller type analog active also...

Page 12: ...ly shielded LF system 210 mm 8 8 Ohms polypropylene cone Midrange system 76 mm 3 8 Ohms soft dome HF system 25 mm 1 6 Ohms Titanium dome tweeter Cabinet finish enamel or nylon fiber flock Cabinet colo...

Page 13: ...K H Vertriebs und Entwicklungsgesellschaft mbH 30900 Wedemark Germany Phone 49 5130 58 48 40 Fax 49 5130 58 48 11 www klein hummel com Printed 08 06 518283...

Reviews: