OPERATION 

SAFETY PRECAUTIONS 

This machine is intended for commercial use. It is 
designed to wet clean carpet and upholstery in a 
indoor environment and is not constructed for any 
other use. Use only recommended cleaning solutions 
and accessory tools. 

All operators must read, understand and practice the 
following safety precautions. 

The following safety alert symbols are used throughout 
this manual as indicated in their description: 

  WARNING: To warn of hazards or unsafe 

practices which could result in severe personal 
injury or death. 

FOR SAFETY: To identify actions which must be 
followed for safe operation of equipment. 

The following information signals potentially dangerous 
conditions to the operator or equipment. 

FOR SAFETY: 

1.  Do not operate machine: 
 

– 

Unless trained and authorized. 

 

– 

Unless operator manual is read and 
understood. 

 

– 

In flammable or explosive areas. 

 

– 

With damaged cord or plug. 

 

If not in proper operating condition. 

 

Unless cord is properly grounded. 

 – In 

outdoor 

areas. 

 – In 

standing 

water. 

 

– 

With the use of an extension cord. 

2. Before 

operating 

machine: 

 

– 

Make sure all safety devices are in place 
and operate properly. 

3. When 

using 

machine: 

 

– 

Do not run machine over cord. 

 

– 

Do not pull machine by plug or cord. 

 

– 

Do not pull cord around sharp edges or 
corners. 

 

– 

Do not unplug by pulling on cord. 

 

– 

Do not stretch cord. 

 

– 

Do not handle plugs with wet hands. 

 

– 

Keep cord away from heated surfaces. 

 

Report machine damage or faulty operation 
immediately. 

 

Follow mixing and handling instructions on 
chemical containers. 

 

Connect hoses before turning on pump. 

 

Be sure chemicals are safe and non-toxic. 

4.  Before leaving or servicing machine: 

 

Turn off machine. 

 

Unplug cord from wall outlet. 

5.  When servicing machine: 

 

Unplug cord from wall outlet. 

 

Avoid moving parts. Do not wear loose 
jackets, shirts, or sleeves. 

 

Use manufacturer supplied or approved 
replacement parts. 

   WARNING: Hazardous Voltage. Shock or 

electrocution can result. Always unplug machine 
before servicing. 

   WARNING: Flammable materials can cause 

an explosion or fire. Do not use flammable 
materials in tank(s). 

   WARNING: Flammable materials or reactive 

metals can cause an explosion or fire. Do not pick 
up. 

   WARNING: Hot solutions up to 88° C (190°F). 

Do not touch with any part of the body. Use 
thermometer to gauge temperature. 

   WARNING: Contents of solution hoses may 

be under pressure even after pump is off. 

 

GROUNDING INSTRUCTIONS 

Machine must be grounded. If it should 
malfunction or breakdown, grounding provides a 
path of least resistance for electrical current to 
reduce the risk of electrical shock. This machine is 
equipped with a cord having an equipment-
grounding connector and grounding plug. The 
plug must be plugged into an appropriate outlet 
that is properly installed in accordance with all 
local codes and ordinances. Do not remove 
ground pin; if missing, replace plug before use. 
International models will have different cord ends.

GROUNDED OUTLET 

           (3 HOLE)

GROUNDING 
        PIN 

Summary of Contents for 36465D3-1

Page 1: ...Rev 00 08 06 36465D3 1 Carpet And Upholstery Cleaner Model No 36465D3 1 11 gal Extractor KLEENRITE 1122 MAPLE STREET MADERA CA 93637 U S A FAX 1 559 673 5725 CUSTOMER SERVICE 1 800 241 4865 Operator and Parts Manual ...

Page 2: ...ies may be ordered by phone or mail from any authorized parts and service center distributor or directly from Kleenrite This machine will provide excellent service However the best results will be obtained at minimum costs if The machine is operated with reasonable care The machine is maintained regularly per the maintenance instructions provided The machine is maintained with manufacturer supplie...

Page 3: ...hands Keep cord away from heated surfaces Report machine damage or faulty operation immediately Follow mixing and handling instructions on chemical containers Connect hoses before turning on pump Be sure chemicals are safe and non toxic 4 Before leaving or servicing machine Turn off machine Unplug cord from wall outlet 5 When servicing machine Unplug cord from wall outlet Avoid moving parts Do not...

Page 4: ... Carefully check carton for signs of damage Report damages at once to carrier The machine is shipped fully assembled and is ready for use 2 Connect hoses and tool to be used Figure1 3 Using a clean bucket or hose fill solution tank with 41 liters 11 gallons of hot water 60 C 140 F maximum Figure 2 WARNING Flammable materials can cause an explosion or fire Do not use flammable materials in tank s 4...

Page 5: ...r 5 minutes to warm up heat exchanger Figure 4 CLEANING CARPETS 1 Turn on vacuum and pump switches Figure 5 2 Take carpet cleaning wand in hand and squeeze valve trigger while moving the tool in short forward and backward strokes Figure 6 WHILE OPERATING 1 Overlap each path by 50 mm 2 in Warning Flammable materials or reactive metals can cause an explosion or fire Do not pick up 2 Periodically che...

Page 6: ...ean water at the end of the day DRAINING SOLUTION TANK 1 Remove empty out nozzle from its storage bracket Figure 10 and attach to end of solution hose 2 Place empty out nozzle over a bucket and turn on pump until all the solution has been pumped from solution tank 3 Replace empty out nozzle to its storage location FREEZE PROTECTION 1 After draining solution tank as described in steps one and two i...

Page 7: ...s 3 Inspect cord and cord grip for damage Replace immediately if damaged 4 Lubricate metal shaft on recovery tank drain with water resistant oil 5 Lubricate female hose couplers with lightweight oil MONTHLY MAINTENANCE Every 80 Hours of Operation 1 Lubricate wheels with water resistant oil 2 Inspect machine for water leaks and loose hardware QUARTERLY MAINTENANCE Every 250 hours of Operation Check...

Page 8: ...nect quick couplers Vacuum motor does not operate Loose or broken wiring Contact Service Center Faulty vacuum switch Contact Service Center Defective vacuum motor Contact Service Center Worn carbon brushes Contact Service Center Poor solution pick up Recovery tank drain valve open Close valve Defective recovery tank lid gasket Replace gasket Clogged float shut off screen Remove recovery tank lid a...

Page 9: ... RECOVERY TANK CAPACITY 38L 10 gal SOLUTION PUMP 120 V 34 5 bar 500psi 3 5 A VACUUM MOTORS 2 STAGE 2 120 V 9 0 A 1080 W HEATER 120 V 14 6 A 1750 W SEALED WATER LIFT 3429 mm 135 in TOTAL POWER CONSUMPTION CIR 1 120V 21A 2520W CIR 2 120V 14 6A 1750W POWER CORDS 2 7 6m 25 ft 3 12 DECIBEL RATING 3 METERS 10 FT FROM MACHINE ON CARPET 68 db A 711 mm 28 in 1016 mm 40 in 450 mm 17 7 in 902 mm 35 5 in ...

Page 10: ...36465D3 1 08 06 10 ELECTRICAL DIAGRAM 36465D3 1 120 V WIRING DIAGRAM ...

Page 11: ...36465D3 1 08 06 11 PARTS LIST 36465D3 1 TANK GROUP ...

Page 12: ...1 Part Description Qty F 13 5 QC 3 8 PLUG BR ST TH 1 F 14 QC 3 8 SOC BR ST TH 1 G 03 19 O RING VITON 2 020 BLKHD 1 J 48GRANITE LID SOLUTION EDGE 2 3 GREY GRANIT 1 J 49GRYGRNT LID MEGA E3 ROTO GREY GRANITE 1 J 57 5 SPACER ROTO 3 OD X 2 4 ID 1 K 09 1 CORD 25 12 3SJT UG 2 K 13 2 LIGHT GREEN ROUND 1 K 13 3 LIGHT RED ROUND 1 K 16 96 BUSHING RELIEF 1 2 NPT 2 K 16 97 NUT NYLON BUSHING REL 1 2 2 K 21W SWI...

Page 13: ...36465D3 1 08 06 13 PARTS LIST 36465D3 1 BASE GROUP ...

Page 14: ...WVL 2 Part Description Qty F 09 Q C 1 4 PLUG BR SHUT OFF 1 G 37 VALVE VAC SHUT OFF DUAL 1 J 45 6BLK PMP MNT DRLD 2 VAC FAN SILNCE B 1 K 17 4 CLAMP NYLON CABLE 1 4 2 K 17 5 CLAMPS NYLON CABLE 3 8 2 K 25 82 THERMOSTAT 190 SPST 1 K 25 83 THERMOSTAT 230 SPST 1 M 0563 85 BRACKET MTR STARTER CAP 500PSI 1 M 0790 5 AXIL ROD 1 2 EDGE ECONO 1 M 0791 AXIL ROD 1 2 EDGE 1 M 0791 01 BRACKET PRES RELFVAL EDGE 1 ...

Page 15: ...OOL 1 1 2 X 6 1 D 15 2 45 ST ELBOW 1 4 NPT 1 D 30 4 FILTER CHECK 100 MESH 1 D 41 NIPPLE 1 4 NPT CLOSE BR 1 PART DESCRIPTION QTY F 09 Q C 1 4 PLUG BR SHUT OFF 1 G 23 VALVE KNGSTN STD S BND 1 H 03 CAP NUT TEE JET BRASS 1 H 18 2 JET 11002 BRASS 1 M 16 5 HOE HANDLE ECONO FLRTL 1 M 16 5A U CLAMP SUPP HOE HNDL EC 1 M 19 5J WAND FLOORTOOL COMP ZOAH 1 SC 82 TRIGGER COMP KNGSTN VALVE 1 SE 06 7 47 HOSE 1 4 ...

Page 16: ...t has been established prior to the request the part will be shipped on an Open Account basis part plus freight A Return Authorization must be requested at the time of order so that the suspected defective part can be returned freight prepaid to Kleenrite for warranty consideration If after receiving the part Kleenrite determines that the part has a manufacturing defect and can be repaired the par...

Page 17: ...than genuine Kleenrite parts will immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Dry cleaning solvents cannot be used in the Edge This warranty shall not cover any Edge machine housing part or assembly if there is evidence of misuse alteration owner neglect lack of prop...

Page 18: ...than genuine Kleenrite parts will immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Dry cleaning solvents cannot be used in the Edge This warranty shall not cover any Edge machine housing part or assembly if there is evidence of misuse alteration owner neglect lack of prop...