the electronics will be still powered.
The reset is automatic when the cooling fan was replaced or the cooling fan problem was solved
and the temperature is in the right functioning parameters.
Troubleshooting guide
4.1
Error Message
Code
Error
Description
Possible Cause
Corrective Action
section
E1
Temperature
sensor
broken.
The control
reads out of
range values.
Bad connection
Temperature sensor
broken.
Check the connectors and
the harness Replace the
sensor
7.14
E2
Temperature
sensor
shorted.
Bad connection
Temperature sensor
broken.
Check the connectors and
the harness Replace the
sensor
7.14
E4
Bad power
board
Bad connection
Temperature sensor
broken.
Check the connectors and
the harness Replace the
sensor
7.14
E8
Latch
mechanism
time-out
overflow
The control
can’t perform
any locking or
unlocking
cycle within
the maximum
allowed time.
Latch mechanism
problem.
Latch motor problem
Replace the motor
7.8
Defective latch micro
switch
Replace the micro switch
7.9
Bad connections
Check the motor
connections and the micro
switches connections
--
E64
Mode selector
disconnected
The control
can’t perform
any cooking
mode.
Bad connection
Selector broken.
Check the connectors and
the harness.
Replace selector
7.17
Failure declarations and error codes
The control is continuously checking the status of the system. If an abnormal condition
is detected for more than 1 minute, a failure occurs:
The heaters and the other loads are disabled.
The display shows a “E” letter followed by a numeric code that depends on the
kind of failure.
The control emits an acoustic warning signal.
To reset a failure declaration, first remove the cause of the failure then turn the selector
to (ZERO) OFF.