background image

POWER AMPLIFIER SECTION                           

EL84’s with 12AX7 driver                         

                                                                         
Rated Power &Load 

18w RMS into 8, 4 ohms 

Power @Clipping (Typically) 

(5%THD, 1 KHZ, 120v AC line) 18W RMS into 8, 4 ohms (Bias must be reduced to

 measure) 

Frequency Response: 

+0,-2db, 50HZ to 15KHZ,@, 20w RMS into 16 ohms 

Hum &Noise: 

Greater than 80 dB below rated power 

Power consumption: 

150wtts    50/60HZ. 120 VAC(domestic) 

PREAMP SECTION 

3-12AX7’s 
The following specs are measured @1KHz with the controls present as follows: 
Pre &Post (lead)@0 
Bass &Treble EQ @12 
Middle 

EQ@0

 

Nominal Level is with Input Gain @6 
MINI level is with Input Gain @ 12 
Preamp Normal Input 

Impedance: Very high Z, 470Kohm 

Lead Channel 

(Post Gain @ 12) 

Nominal Input level –40dBv, 10mV RMS 
MINI Input Level: -70 dBV, 0.3mV RMS 
Normal Channel: 
Nominal Input Level: 
-17 dBV , 140mV RMS 
MINI Input Level: -28dBV, 40mVRMS 
Max Input Level: 0dBV 1.0VRMS 

Equalization: 

Customer bass, middle & treble passive-type EQ 
Designed input Level: 
-6dBV ,0.5VRMS   

IMPORTANT SAFETY INSTRU

IMPORTANT SAFETY INSTRU

IMPORTANT SAFETY INSTRU

IMPORTANT SAFETY INSTRUCTIONS

CTIONS

CTIONS

CTIONS 

 

 

 

WARNING

WARNING

WARNING

WARNING:

:

:

When  using  electric  products,  basic  cautions  should  always  be 

followed. 
1.

 

Read all safety and operating instructions before using this product. 

2.

 

All safety and operating instructions should be retained for future reference. 

3.

 

Obey all cautions in the operating instructions and on the back of the unit. 

4.

 

All operating instructions should be followed. 

5.

 

This  production  should  not  be  used  near  water,  i.e..  a  bathroom  ,  sink, 
swimming pool, wet basement, etc. 

6.

 

This product should not be placed near a source of heat such as a stove, 
radiator, or another heat producing amplifier. 

7.

 

This product should be located so that its position does not interfere with its 
proper ventilation. It should not be placed flat against a wall or placed in a 
built-in enclosure that will impede the flow of cooling air 

8.

 

Connect only to a power supply of the type marked on the unit adjacent to 
the power supply cord. 

9.

 

Never break off the ground pin on the power supply cord 

Reviews: