EU-DOC/02-2018/11 -USA- 

EU-DECLARATION OF CONFORMITY 

 

Klay Instruments B.V.

 

Nijverheidsweg 5, 7991 CZ Dwingeloo, The Netherlands 

Certify that the equipment intended for use in potentially explosive atmospheres, only new products, indicated here 
after: 
 

 

 

Electronic Pressure- and Level Transmitters 

Series 8000-SAN, Series 8000, Series CER-8000 

Hydrobar-Cable, Hydrobar-EXTD, Hydrobar-FR 

Are in accordance with: 
-  Directive 2014/34/EU (Equipment and protective systems intended for use in potentially explosive atmospheres) 
-  Directive 2014/30/EU (Electro Magnetic Compatibility). 
-  Harmonized standards: 

 

EN 60079-0: 2012  (General rules) 

 

EN 60079-11: 2012 

(Intrinsic safety “i”)  

 

EN 60079-26:2007 (Group II cat. 1G requirements) 

 

IEC 61000-6-2: 2001 (EMC, Immunity in industrial location) 

 

IEC 61000-6-3: 2001 (EMC, Emission in industrial location) 

 

IEC 61000-6-4: 2001 (EMC, Emission in industrial location) 

 

EN-ISO-IEC 80079-34: 2011 (Potentially explosive atmospheres 

– Application of quality systems  

 

The type (protection mode “ia”) which has been the subject of; 

EC-type Examination Certificate Numbers: 

 

KEMA 03 ATEX1219 X, Issue 5 
Delivered by the KEMA, Meander 1051, 6825 MJ  Arnhem, The Netherlands, Notified Body No. 0344.  
 
Manufacturing plant in Dwingeloo which has been the subject of; 

Production Quality Assurance Notification Number: 

DEKRA 12ATEXQ0041, Issue 3 
Delivered by the DEKRA, Meander 1051, 6825 MJ  Arnhem, The Netherlands, Notified Body No. 0344. 

   
  Date: February 12

th

 2018 

 
E. Timmer 
Managing Director - Klay Instruments B.V. 

Signature:

 

 

 

 

  The marking of the equipment is as follows: 

II 1G Ex ia IIC T4 Ga 

 

‘’II’’  means that the equipment has been built for use in surface industries (and not in mines endangered by 

firedamp). 

 

‘’1’’  equipment for use in Zone 0 (if G) 

 

‘’G’’  equipment for use with gas, vapours or mists 

 

‘’Ex’’  equipment in compliance with European standards for  

explosive atmospheres 

 

‘’ia’’  equipment in compliance with specific building rules for intrinsically save equipment 

 

‘’C’’  equipment for use with gas of subdivision C 

  ‘’T4’’  equipment whose surface temperature does not exceed 135°C when used with ambient temperature < 70

°

C. 

  Protection Grade, Series 8000-SAN, 8000, CER-8000, 

IP 66

 

Protection Grade, Series Hydrobar-cable, Hydrobar-EXTD, 

IP 66

 

The Hydrobar-FR and all other submersible parts from the Series Hydrobar are  IP 68. 

Furthermore, whatever the protection mode, only use cable glands with a protection degree of at least IP 66. 
Be sure the cable diameter complies with the selected cable gland. Tighten the cable gland in a proper way. 
Never forget to mount the covers of the electronics housings in a proper  way. 

For other technical details, refer to the instruction manuals of the series transmitters.    

 
 

 

 
 

Nijverheidsweg 5 

7991 CZ Dwingeloo 

Tel.:  +31 521 591550   

The Netherlands 

P.O. Box  13 

 

7991 AA Dwingeloo 

Fax.:  +31 521 592046   

e-mail: [email protected] 

 
 

Summary of Contents for PERAMIC

Page 1: ...C The PERAMIC has no oil filling system so the process pressure is applied directly to the ceramic pressure cell The voltage signal from the ceramic cell is connected directly to the Integrated Circuit that converts this signal into 4 20 mA Therefore the PERAMIC has a perfect linearity and is fully temperature compensated This means that various process temperatures have no effect on the accuracy ...

Page 2: ...dc min power supply 20 mA CALIBRATION All transmitters are fully calibrated at the factory to customer specified range When no calibration is requested the transmitter will be calibrated at the lowest span It is advisable to recalibrate the transmitter after shipment The calibration sequence is as follows 1 The output of the transmitter must be set at 4 mA Zero potentiometer 2 Air pressure in acco...

Page 3: ... mA Ci 1 nF Li 1 2 mH Pi 0 9 W 30 C Tamb 70 C 22 F Tamb 158 F All certifications are in compliance with IECEx scheme rules and the International Standards IEC 60079 0 2011 IEC 60079 11 2011 IEC 60079 26 2007 and IEC 17050 1 They are certified for use in hazardous areas by DEKRA B V DO NOT REMOVE THE SCREW COVER WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT FUNCTIONAL SAFETY SIL The device is certifi...

Page 4: ...ater jets on the diaphragm take necessary steps to avoid this Guarantee will not be granted As soon as the wiring is brought inside through the PG9 Cable gland and connected to the terminal board make sure the cable gland is tightly fixed so that moisture cannot enter into the electronic housing Never remove the venting 3 because it is especially designed to prevent moisture from entering into the...

Page 5: ...A 12ATEXQ0041 Issue 3 Delivered by the DEKRA Meander 1051 6825 MJ Arnhem The Netherlands Notified Body No 0344 Date February 12 th 2018 E Timmer Managing Director Klay Instruments B V Signature The marking of the equipment is as follows II 1G Ex ia IIC T4 Ga II means that the equipment has been built for use in surface industries and not in mines endangered by firedamp 1 equipment for use in Zone ...

Reviews: