Quadigy

 

Quad Envelope Generator

 

7-stage envelopes, presets, cycling, morphing & CV matrix 

Introduction 

The Quadigy is a complex envelope generator focused on live play. The goal is to allow the user 
setting up rich, interactive and dynamically evolving envelopes without the risk of breaking up a 
subtle and intricate patch once on stage. This is achieved by offering two main modes, one where 
full control is available, and a Live mode where only the settings that are sensible using on stage 
are accessible. The user interface offers an intuitive access for otherwise complex settings. 
Advanced features such as automatic time-stretching, multiphase clocking and full morphing 
between presets put the Quadigy in a category on its own.   

 

Env 4

CV A

G/T 3

G/T 2

G/T 1

Quadigy

Quad Programmable Envelope Generator

G/T 4

Env 2

Env 3

Env 1

CV B

Klavis

Clock

1

2

3

4

User

R

S

D

A

DL

H

EG

CV Matrix

Global

Cycle

Preset

U

A

B

Liv

e

Preset/Edit

 

Features at a glance 

 

Quad 7-stage envelopes 

o

 

Pre-delay 

o

 

Hold 

o

 

Attack 

o

 

Punch 

o

 

Decay 

o

 

Sustain 

o

 

Release 

 

Continuous curve shape settings 

 

Inversion 

 

Independent output level  

 

Cycle capability with auto fit-to-clock 

o

 

Elastic time stretching 

o

 

5 internal clocks with tap tempo 

o

 

External clock control 

o

 

Multiply/divide and offset 

o

 

Individual cycle ext. control 

 

Manual gating for convenient editing 

 

32 presets with naming 

 

External preset control via CV or Trig 

 

Simultaneous 156-point CV matrix  

 

Morphing on presets and CV Matrix 

 

Multi-editing for easy polyphonic uses 

 

Live mode for easier/safer control 

 

Graphical display 

 

Real-time envelope stages LED indication 

 

Current state retained over power cycle 

 

Easy firmware update via an audio file 

 

Skiff-friendly and compact module 

 

Summary of Contents for Quadigy

Page 1: ...nv 4 CV A G T 3 G T 2 G T 1 Quadigy Quad Programmable Envelope Generator G T 4 Env 2 Env 3 Env 1 CV B Klavis Clock 1 2 3 4 User R S D A DL H EG CV Matrix Global Cycle Preset U A B Live Preset Edit Fea...

Page 2: ...supply This is done by adding up the current draw of all modules mA separately for each of 5V 12V and 12V rails If any of these 3 sums exceeds the available current of your supply for that voltage do...

Page 3: ...is progressing a row is filling up When the row is full all green LEDs flash the firmware is updated successfully Press any button to restart the module If the sound level is too low Stop audio playba...

Page 4: ...scovery go to the Run through demo on page 15 Live mode vs Studio mode Hidden settings The Quadigy offers many features whose editing is not required or sensible in a live context In Live mode some ed...

Page 5: ...e values to all envelopes selected Faders and User knob behavior Changes are applied after the physical position crosses the current value This is shown by the fader s red LED going solid on A current...

Page 6: ...ation links can be active simultaneously if you wish so we think not but who are we to judge The 3 sources are CV A CV B and the User knob acting as CV U Assigning a CV modulation Every page whose set...

Page 7: ...is menu offers 3 Quad fader pages with encoder press manual gate o ADSR o Additional timings Pre delay Hold Punch and Global Time o Curves for A D R and output level 5 Parameter pages o Trigger mode G...

Page 8: ...immediately to Release from the level currently reached Punch time If Attack has the time to reach the maximum level the Punch phase begins Punch is a hold time before the Decay begins The Punch leve...

Page 9: ...ime is at 0 any envelope is reduced to a pulse Output Level This sets the voltage span of the envelope signal At maximum the envelope goes up to 8 Volts Note that CV control of this setting offers a v...

Page 10: ...s setting is off When set to on the polarity of the envelope is flipped Note that the signal remains unipolar positive there are no negative voltages generated Morph Time duration This per preset sett...

Page 11: ...f the various phases A D etc become percentages of the overall envelope duration This is what allows automatic time stretching If for example you augment the attack time all other duration will be pro...

Page 12: ...cycle 1 cycle 1 cycle 1 cycle Ext Global clock Post divider cycle e g Div 4 1 cycle User defined cycle start e g Subdiv 3 12 Offset points auto generated Filling 100 Offset 0 Filling 75 Offset 0 Filli...

Page 13: ...n Parameter on the fader Off GT Global stretch squeeze Internal clock Metronome Tempo for the section Internal global clock Metronome G Tempo for all sections in Global clock External clock Sweeping c...

Page 14: ...e first and last preset in the range accessible by external preset control Morph mode page Defines where the Morph duration will be read from when calling a new preset As defined in each preset Global...

Page 15: ...cess to parallel editing and manual gating of these two envelopes Every press on the encoder is a manual gate on the selected envelopes Global timing Turn the User knob until its red LED goes on then...

Page 16: ...display and the signal on the output 3 green LED The knob changes the A R settings in opposite polarities The change in shape is not affecting the tempo The knob could have also varied the tempo the...

Page 17: ...draw 12V 24 mA 12V 10 mA 5V 40 mA Input output All inputs and outputs can withstand signals between 12V and 12V without harm Jack Effective voltage range received or generated Gate Trigger input Minim...

Reviews: