9
---- Press power button for the fifth time to shut down humidifier.
5.
Set Timer:
--- Under low, medium or strong mist level, press power button for 3 seconds to enter 2 hours
timer setting, indication light flashing.
Press power button for 3
seconds
Indicator light (flash)
Preset time
Low
orange
2 hours
Medium
Green
2 hours
Strong
Blue
2 hours
--- Press power button for 3 seconds again, timer is cancelled and a beep is heard.
6. When water tank is out of water, humidifier will shut down automatically for safety purpose.
7. After continuous of 10 hrs use, allow it to rest for 2 hrs before next use.
Attention Operation:
Use of this humidifier, the safety measures necessary to comply with the following:
Carefully read all the instructions, even if you are very familiar with this product.
Before connected with the power, please check your home used by the voltage and humidifier in the mark
in line voltage. If the voltage does not match, please contact the dealer for replacing correct voltage
product.
Do not heat near the surface at any place using this machine.
Machinery as far as possible away from furniture and electrical products.
Do not touch water and transducer in the mainframe base when in operation.
Do not turn unit on when water tank is empty.
Do not immerse the mainframe base in water.
Disconnect power supply before cleaning or servicing unit.
Enter tap water below 40
℃
.
Maintenance and Cleaning:
1. Before cleaning, Please cut off electricity.
2. Lift water tank away and pour off remaining water in mainframe.
3. Pour cleaning solution into water tank.
4. Use a soft brush or cloth to clean water tank.
5. Use a soft brush to clean water line inductor. Do remove all scale and make it clean.
6. Pour off cleaning solution in tank.
7. Use clear water to clean tank.
8. Strictly prohibit change transducer, which may cause no mist production.
Common Trouble Shooting
If your humidifier does not work, you can consult the following meansures:
Trouble
Possible reasons
Shooting way
Power lamp off
No power supply
Connect power supply, switch on
Power lamp on, no mist
outlet with wind
No water in water tank
Fill water into water tank
Security switch is too slight.
Make the switch tight.
Abnormal smell mist
New unit
Take out water tank, open cover, let is
stay 12 hours in cool position.
Dirty water or long time staying
water.
Cleaning water tank, fill in clear water.