32
EN
32
•
The exhaust air line should be as short and straight as possible.
•
To avoid excessive noise or a reduced extraction capacity the diameter of the
exhaust air pipeline should not be less than 150 mm.
• Use or form only large radius bends. Small radius bends reduce the extraction
capacity of the hood.
•
Use only smooth pipelines or flexible hoses of non-flammable materials for
the exhaust air pipeline
• If the exhaust air pipeline is horizontally routed, there must be a minimum
gradient of 1 cm per metre or an inclination angle of 2°. (Fig. C) Otherwise
condensation water could run into the extractor hood motor.
• If the exhaust air is directed into an exhaust air duct, the end of the entry
fitting must be directed in the direction of flow.
•
If the exhaust air pipeline is routed though cool rooms, lofts etc. There can be
a large temperature drop within the individual parts of the pipeline, resulting
in sweating or condensation water production. This renders outlet pipeline
insulation necessary.
• In some cases a condensation water barrier must be installed in addition to
adequate insulation.
•
The manufacturer is constantly working on the further development of
its products. Please note that product changes in form, equipment and
technology are not excluded.
•
The manufacturer shall not be liable for any errors resulting from non-
compliance with the above information and provisions.
Summary of Contents for 10038406
Page 2: ......
Page 8: ...8 DE Einbauma e 597 95 Installation 10038406 Schnittlochgr e 597 x 95 mm Schrank...
Page 10: ...10 DE...
Page 28: ...28 EN Installation dimensions 597 95 Installation 10038406 Cut hole size 597 x 95 mm Cabinet...
Page 30: ...30 EN...
Page 48: ...48 FR...
Page 66: ...66 ES...
Page 84: ...84 IT...
Page 95: ......
Page 96: ......