64
EN
Notes on Boost Function
In this hob every zone can work with Boost function. If you need to use boost please
switch off the other zone in the same group first. Otherwise the and symbols will flash
on the display of the selected zone and power level is automatically set.
Note:
When not using boost function, you can use all four zones at the same time.
Power management function
•
Cooking zones are divided into two groups. Each group has a maximum electricity
loading of 3700 W. Group (b) has the power management function which
activates when the total electricity loading of the cooking zones exceeds 3700W.
The power management function decreases the power to the other cooking zones
and changes the displayed power level accordingly. The heat setting display of the
reduced zone(s) changes between four levels, e.g. if all zones are on, the highest
power levels of three zones are decrease to level 5 (1200W), level 5 (1200W)
and level 7 (1200W).
•
In Group (a) both cook zones can work at full power any time as the maximum
combined power is 3300W. In Group (b) if two zones are working and you switch
on the third zone, the power of the third zone will be reduced to level 7 (1200W)
and the other two zones will drop to level 5 (1200W) automatically. If you want the
third zone to work at level 9 (1800W or 1500W) you must turn off the other two
zones.