21
Lighting
After the hood slides up, the lights will turn on automatically in 8-10 seconds.
• Touch the button of LIGHT, lights will turn off. Touch the LIGHT button again, the lights will turn off.
• When you touch the button of LIGHT, the pilot light is flashing. Use the SLIDE CONTROL to control the
light intensity when the pilot light is flashing. When enter into the controlling of light intensity, the silde
button control the light intensity. There is 8 speeds of slide button when lighting, every speed means one
light intensity. When touch SLIDE CONTROL and slide to one light and it will be on, the light will be on in
corresponding light intensity. The pilot light will stop flashing after 15s if no function adjustment.
Timer Setting
• Touch TIMER button when light or motor is working; the hood will enter into timer working. When the
pilot light of timer is flashing, slide button to select the timer section. There are eight sections of timer
button when timer is working, they are: 5-10-15-20-25-30-35-40, touch the TIMER button to enter into
timer working when confirm the timer section. Or, enter into timer working automatically 5s later. The
motor and light are off automatically when finish the timer, the hood will enter into standby, the decora-
tive cover will close automatically.
• Use the timer function again when keep power on, touch the timer button but without time setting, the
hood will keep the time which setted on last time. It will decrease by second after 5s.It will work as new
time after new setting.
• Touch the SPEED button or control the LIGHT intensity when timer is working, the timer function will
cancel automatically.
Troubleshooting
Problem
Possible Cause
Suggested Solution
Light on, but motor
does not work.
The leaf blocked.
Get rid of the blocking.
The capacitor damaged.
Replace capacitor.
The motor jammed bearing
damaged.
Replace motor.
Light does not work,
motor does not work.
Light damaged.
Replace lights.
Power cord looses.
Connect the wires as per the electric diagram.
Oil leakage.
One way valve and the air
ventilation entrance are not tightly
sealed.
Take down the one way valve and seal with
glue.
Leakage from the connection of
U-shaped section and cover.
Take U-shaped section down and seal with
soap or paint.