51
Wiring Diagram
With a Multi indoor unit, install as described in the installation manual supplied with the Multi outdoor unit. Live
the sensor securing plate, remove the front metal plate cover, and connect the branch wiring to the terminal
block.
• Strip wire ends (15mm)
• Mach wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw
wires to the corresponding terminals.
• Connect the earth wires to the corresponding terminals.
• Pull wires to make sure that they are securely latches up, then retain wires with wire retainer.
Important Hints on Wiring
• Do not use tapped wires, stranded wires, extensioncords, or starburst connections, as they may cause over-
heating, electrical shock, or fire.
• Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain
pump, etc, from the terminal block.) Doing so may cause electric shock or fire.)
Outdoor Unit Installation
Where to install Outdoor Unit
• The foundation must be solid enough to bear
the weight and vibration of the unit.
• The space around the unit is adequate for ven-
tilation.
• The location is not close to any flamable gases
• The location is sufficiently isolated so that the
running noise and the hot exhaust air do not
disturb the users or their neighbors.
• Easy access to check and to maintain.
• Ensure the spaces indicated by arrows from the
wall,ceiling fence,or other obstacles.
Terminal block
Firmly fix the wires with
the terminal screws
When wire length exceeds
10m, use 2.0mm diameter
wires
Firmly fix the wires with the
terminal screws
Sensor securing plate
Front metal
plate cover
Electrical
component box
Wire retainer
Shape wires so that
the front metal
plate cover will fit
securely.
Firmly secure wire
retainer so that
wires sustain no
external stress.