IMPORTANT SAFETY INSTRUCTIONS

These symbols are internationally accepted symbols that warn of potential hazards with
electrical products.

The lightning flash with arrowhead symbol, within an equilateral
triangle is intended to alert the user to the presence of uninsulated
“dangerous voltage” within the product's enclosure that may be of
sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert
the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the appliance.

1. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with a dry cloth.

7. Do not block any of the ventilation openings. Install in accordance with the manufacturers
instructions.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that
produce heat.

9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two
blades with one wider than the other. A grounding type plug has two blades and a third grounding
prong. The wide blade or third prong are provided for your safety. When the provided plug does not fit into
your outlet, consult an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the point where they exit from the apparatus.

11. Unplug this apparatus during lightning storms or when unused for long periods of time.

12. Refer all testing to qualified personnel. Servicing is required when the apparatus is damaged in any way,
such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING

:

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,

DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE

AVIS

:

RISQUÉ DE CHOC ELETRIQUE. NE PAS OUVRIR

Summary of Contents for DN500 Plus

Page 1: ...knik Group Klark Teknik Building Walter Nash Road Kidderminster Worcestershire DY11 7HJ England Tel 44 1562 741515 Fax 44 1562 745371 Email sales ktgplc com Website www klarkteknik com OPERATORS MANUA...

Page 2: ......

Page 3: ...stoves or other apparatus that produceheat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type pl...

Page 4: ......

Page 5: ...k Teknik Group UK PLC Walter Nash Road Kidderminster Worcestershire DY11 7HJ England Tel 44 1562 741515 Fax 44 1562 745371 Company Registration No 2414018 abc abc SIGN A L P ROC ES S IN G BY D EFIN IT...

Page 6: ......

Page 7: ...Using the DN500 13 Compression Expansion and Limiting together 20 Application notes Technical Specification 25 Front panel controls 7 Rear panel controls 8 14 Setting the Controls 15 17 Setting the Co...

Page 8: ...l abc...

Page 9: ...ad should never be disconnected To prevent shock or fire hazard do not expose the unit to rain or moisture To avoid electrical shock do not removecovers Referservicingtoqualifiedpersonnelonly This pro...

Page 10: ...2 l abc...

Page 11: ...ty control inspection and every possible effort has been made to ensure that it left the factory in perfectcondition If however the unit shows any signs of damage please notify the transportation comp...

Page 12: ...4 l abc...

Page 13: ...he DN500 offers variable ratio expansion which can be used to increase subtly the dynamicrangeof asignal or toactasaconventionalnoisegate or offeranydegreeof expansioninbetween To control signal peaks...

Page 14: ...6 l abc...

Page 15: ...levels 4 sets the time taken for compression to commence after the threshold is exceeded from 0 05 milliseconds 50 microseconds to20 milliseconds 5 determines the time taken for the gain to return to...

Page 16: ...esholdlevel adjustablefrom40 millisecondsto2seconds 13 Attack is a switched control offering either automatic signal monitored setting of Expander attacktimeorafixedvalueof2milliseconds 14 is the outp...

Page 17: ...theunit Mains mains fuse Voltage selector switch Note Units for the Japanese market do not have an accessible mains voltage selector switch and are set for 100V operationonly 22 Signal is madeviaafema...

Page 18: ...l abc 10...

Page 19: ...e available and may be retrospectively fitted Please contact your Klark Teknik representative for more information The output circuitry is capable ofdrivinga600 ohmloadatalevelof 22dBu 2 1 3 1 2 3 2 1...

Page 20: ...y Transformer or electronically balanced connections have the benefit of Common Mode Rejection which eliminates externally induced interference such as mains hum etc Balancing is especially useful whe...

Page 21: ...Almost always it is necessary to compress the dynamic range of natural sounds to fit them into a window suitablebothfor theequipmentandfor comfortablelistening Although the dynamic range of the progr...

Page 22: ...helevelofavocalmayvarywidely andappearliketheunprocessed signalinthediagram The unprocessed signal has a large dynamic range between the highest and lowest levels Applying compression reduces the high...

Page 23: ...of 2 1 the effect is mild and suitable for the subtle compression of vocals or of a complete mix At 12 1 compression is becoming stronger and more noticeable Ratios between 3 1 and 15 1 are suitable...

Page 24: ...release time will mean that the gain will stayatitsreducedlevel onlyrecoveringgradually The setting of the correct release time is a compromise If the release time is too short background noise can ca...

Page 25: ...arder action of anoisegate The unprocessed signal has a fairly narrow dynamic range between the highest and lowest levels Expansion makesthelowerlevelslowerstill increasingthedynamicrange Used as an e...

Page 26: ...gate The light bar graph indicatestheamountof gainreductiontakingplace sets the time the Expander takes to respond once the signal has passed below the threshold This can be done automatically the ci...

Page 27: ...te control over peak levels is required a Peak Clipper may be switched in acting in effect as a compressor witharatioof infinity 1andaninstantaneousattacktime sets thelevelabovewhichlimiting or slippi...

Page 28: ...ed also to clean up thesignal TheLimiter Clipperwillcontrolanyunwantedpeaks Theresultisthree stagedynamiccontrolover gainwiththreedifferentthresholdlevels In the mid range of levels the signal is unal...

Page 29: ...signal chain its operation is unaffected by the use of any of the console controls except Input Gain An alternativeisconnectiontothegroup insertpointof theconsole This connection has two uses the inpu...

Page 30: ...pander In normal use the amount of compression or expansion is related to the dynamics of the input signal The Side Chain allows the signal passing through the unit to be controlled by the dynamics of...

Page 31: ...cond channel is equalised so that high frequencies in the sibilant range are boosted This channel is fed via an auxiliaryoutputtotheCompressor SideChaininput Now the Compressor will react whenever the...

Page 32: ...l abc 24...

Page 33: ...ut Noise 94dBu 20Hz 20kHz unweighted Threshold 30dB to 20dB Ratio 1 1 to 50 1 Knee 1dB hard to 40dB soft Envelope switchable auto attack and release controls disabled Attack 90 capture 0 05ms to 20ms...

Page 34: ...ittable and has to be specified with order Security cover Transformer input output balancing Input transformer balancing is non retrofittable and has to be specified with order Parts Number Perspex se...

Reviews: