9
all the high-voltage capacitors before measuring
resistance.
To measure resistance, connect the Meter as follows:
·
Set the rotary switch to desired
Ω
range
.
·
Connect the RED test lead into “V
Ω
mA” input terminal and
BLACK test lead into “COM” input terminal.
·
Connect the test leads across with the object being
measured.
·
Read the value from display.
·
Press HOLD button if need.
Warning
a) Do not apply any voltage to the input when the Meter is
working in resistance measuring mode.
b) If resistance of the circuit or resistor be measured is
open or higher than the range be selected the display
will show “1”.
c) For low resistance measurement, it maybe make
some additional error due to the resistance of the test
leads, at this case, as a tip you can short the test leads
firstly and record down the resistance, then subtract it
from the measuring value to obtain the more accurate
result. If the short resistance of the test leads is up to
0.5
Ω
, it is need to double check if the test leads are
loosened or other troubles exist.
d) It is normal for taking a couple of seconds to get the