32
5.0
Inspection
5.1 General
5.1.1 The inspection procedure herein is based on ANSI/ASME B30.16. The following definitions are from
ANSI/ASME B30.16 and pertain to the inspection procedure below.
Designated Person
- a person selected or assigned as being competent to perform the specific duties to
which he/she is assigned.
Qualified Person
- a person who, by possession of a recognized degree or certificate of professional
standing, or who, by extensive knowledge, training, and experience, has successfully demonstrated the
ability to solve or resolve problems relating to the subject matter and work.
Normal Service
- that distributed service which involves operation with randomly distributed loads within
the rated load limit, or uniform loads less than 65% of rated load for not more than 25% of the time.
Heavy Service
- that service which involves operation within the rated load limit which exceeds normal
service.
Severe Service
- that service which involves normal or heavy service with abnormal operating
conditions.
5.2 Inspection Classification
5.2.1 Initial Inspection - prior to initial use, all new, re-installed, altered, or modified trolleys shall be inspected
by a designated person to ensure compliance with the applicable provisions of this manual.
5.2.2 Inspection Classification - the inspection procedure for trolleys in regular service is divided into two
general classifications based upon the intervals at which inspection should be performed. The intervals
in turn are dependent upon the nature of the critical components of the trolley and the degree of their
exposure to wear, deterioration, or malfunction. The two general classifications are herein designated as
FREQUENT and PERIODIC, with respective intervals between inspections as defined below.
5.2.3 FREQUENT Inspection - visual examinations by the operator or other designated personnel with
intervals per the following criteria:
Normal service - monthly
Heavy service - weekly to monthly
Severe service - daily to weekly
Special or infrequent service - as recommended by a qualified person before and after each
occurrence.
5.2.4 PERIODIC Inspection - visual inspection by a designated person with intervals per the following criteria:
Normal service - yearly
Heavy service - semiannually
Severe service – quarterly
Special or infrequent service - as recommended by a qualified person before the first such
occurrence and as directed by the qualified person for any subsequent occurrences.
Summary of Contents for SMR2Q Series
Page 44: ...This Page Intentionally Left Blank...
Page 46: ...46 9 1 Electric Parts Figure 9 1 1 Electric Parts...
Page 48: ...48 9 2 Pendant and Power Supply Parts Figure 9 2 1 Pendant and Power Supply Parts...
Page 50: ...50 9 3 Side Plates and Suspension Parts Figure 9 3 1 Side Plates and Suspension Parts...
Page 52: ...52 9 4 Motor Parts Figure 9 4 1 Motor Parts...
Page 54: ...This Page Intentionally Left Blank...
Page 55: ...This Page Intentionally Left Blank...
Page 56: ...www kito ca...