Electrical Requirements: 

U.S.A. Only

IMPORTANT:

 The cooktop must be electrically grounded in 

accordance with local codes and ordinances or, in the absence 

of local codes, with the National Electrical Code, ANSI/NFPA 70 

or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system 

that will not operate if plugged into an outlet that is not properly 

polarized.
If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrical installer determine that 

the ground path is adequate.
A copy of the above code standards can be obtained from:

National Fire Protection Association 

1 Batterymarch Park 

Quincy, MA 02169‑7471

CSA International 

8501 East Pleasant Valley Road 

Cleveland, Ohio 44131‑5575

 

A 120 V, 60 Hz, AC‑only, 15 A, fused electrical circuit 

is required. A time‑delay fuse or circuit breaker is also 

recommended. It is recommended that a separate circuit 

serving only this cooktop be provided.

 

Electronic ignition systems operate within wide voltage limits, 

but proper grounding and polarity are necessary. Check that 

the outlet provides 120 V power and is correctly grounded.

 

The wiring diagrams are provided with this cooktop. The 

wiring diagrams are located inside the control console.

Gas Supply Requirements

Observe all governing codes and ordinances.

IMPORTANT: 

This installation must conform with all local codes 

and ordinances. In the absence of local codes, installation must 

conform with American National Standard, National Fuel Gas 

Code ANSI Z223.1 — latest edition — or CAN/CGA B149 — 

latest edition.

IMPORTANT:

 Cooktop must be connected to a regulated 

gas supply.

IMPORTANT: 

Leak testing of the cooktop must be conducted 

according to the manufacturer’s instructions.

Type of Gas

Natural Gas:

This cooktop is factory set for use with Natural gas. The model/

serial/rating plate, located under the console on the right‑hand 

side, has information on the types of gas that can be used. If 

the types of gas listed do not include the type of gas available, 

check with the local gas supplier.

Propane Gas conversion:

Conversion must be done by a qualified service technician. 
No attempt shall be made to convert the cooktop from the gas 

specified on the model/serial/rating plate for use with a different 

gas without consulting the serving gas supplier. To convert to 

Propane gas, use the Propane gas conversion kit provided with 

your cooktop and see the “Gas Conversions” section. The parts 

for this kit are in the package containing literature supplied with 

the cooktop.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make 

sure gas pressure does not exceed 14" (36 cm) water 

column. 
Examples of a qualified person include: 
licensed heating personnel, 

authorized gas company personnel, and

authorized service personnel.
Failure to do so can result in death, explosion, or fire.

Summary of Contents for W11179813A

Page 1: ...EXIGENCES D INSTALLATION 21 Outils et pièces 21 Exigences d emplacement 22 Spécifications électriques É U seulement 25 Spécifications de l alimentation en gaz 25 INSTRUCTIONS D INSTALLATION 27 Installation de la table de cuisson 27 Raccordement au gaz 27 Installer le plateau d égouttement 28 Terminer l installation 29 CONVERSIONS POUR CHANGEMENT DE GAZ 30 Conversion pour l alimentation au propane ...

Page 2: ...ctrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that y...

Page 3: ... personal injury or unintended operation In the State of Massachusetts the following installation instructions apply Installations and repairs must be performed by a qualified or licensed contractor plumber or gas fitter qualified or licensed by the State of Massachusetts Acceptable Shut off Devices Gas Cocks and Ball Valves installed for use shall be listed A flexible gas connector when used must...

Page 4: ...ker or pencil Pipe wrench Flat blade screwdriver 15 16 24 mm combination wrench Wrench or channel lock pliers Pipe joint compound resistant to Propane gas Noncorrosive leak detection solution For Propane Natural Gas Conversions Adjustable wrench Drive ratchet Large flat blade screwdriver T20 Torx Driver Masking tape 1 2 1 3 cm open end wrench 1 Square Driver TORX and T20 are trademarks of Acument ...

Page 5: ...ings in the wall or floor where cooktop is to be installed must be sealed Do not seal the cooktop to the side cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See the Electrical Requirements section Proper gas supply connection must be available See the Gas Supply Requirements section IMPORTANT To avoid d...

Page 6: ...74 6 cm B 11 4 3 2 cm C Island trim or optional backguard D 77 16 18 8 cm E Gas inlet is located 17 8 4 8 cm from the back of the cooktop burner base and 47 8 12 4 cm in from left hand side of the cooktop burner base F 22 55 9 cm G 35 8 9 2 cm A 277 8 70 8 cm B 353 4 90 8 cm C 3 prong grounding type power supply cord D Model serial rating plate located on the underside of the cooktop burner base A...

Page 7: ...ove the cooktop surface NOTE Due to manufacturing factory tolerances these are nominal dimensions You may need to readjust to meet your clearance A B C D A Grounded 3 prong outlet should be located on left hand side of the cutout 16 40 6 cm max from enclosure sidewall B 10 25 4 cm min clearance from countertop to top of the outlet C 14 35 6 cm countertop to the gas supply line D Gas supply line sh...

Page 8: ...des and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 latest edition IMPORTANT Cooktop must be connected to a regulated gas supply IMPORTANT Leak testing of the cooktop must be conducted according to the manufacturer s instructions Type of Gas Natural Gas This cooktop is factory s...

Page 9: ... Pressure Regulator The gas pressure regulator supplied with this cooktop must be used The inlet pressure to the regulator should be as follows for proper operation Natural Gas Minimum pressure 5 12 7 cm WCP Maximum pressure 14 35 6 cm WCP Propane Gas Minimum pressure 10 25 4 cm WCP Maximum pressure 14 35 6 cm WCP Contact local gas supplier if you are not sure about the inlet pressure Burner Input...

Page 10: ...be used to connect the cooktop to the existing gas line The following shows a typical connection Your connection may be different according to the supply line type size and location 3 Install the pressure regulator with the arrow pointing up toward the bottom of the cooktop burner base and in a position where you can reach the regulator cap IMPORTANT All connections must be wrench tightened Do not...

Page 11: ... handle is parallel to the gas pipe 2 Test all connections by brushing on an approved noncorrosive leak detection solution If bubbles appear a leak is indicated Correct any leak found 3 Remove cooktop burner caps and grates from parts package Place burner caps on burner bases Place grates over burners and caps 4 Plug into a grounded 3 prong outlet 5 Check the operation of the surface burners See C...

Page 12: ...ile the line clears The surface burners and grill flames should light within 4 seconds The first time a burner is lit it may take longer than 4 seconds to light because of air in the gas line After verifying the proper burner operation turn the Control Knobs to OFF If burners do not light properly Turn Cooktop Control Knob to OFF Check that the cooktop is plugged in and the circuit breaker has not...

Page 13: ...ure Testing Gas supply pressure for testing regulator must be at least 1 2 5 cm water column pressure above the manifold pressure shown on the model serial rating plate Line pressure testing above 1 2 psi 3 5 kPa gauge 14 35 6 cm WCP The cooktop and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in e...

Page 14: ...er is snug to cooktop do not over tighten 8 Replace burner cap 9 Repeat steps 2 through 8 for the remaining burners 10 Remove the control knobs and bezels for surface burners by using the 1 Square driver Adjusting Simmer Low Setting on Surface Burners for Propane 1 Unplug cooktop or disconnect power 2 Using the square bit screwdriver remove the surface burner control knobs and bezels 3 Remove the ...

Page 15: ... Check that the control console is flush with the top edge of the cooktop 10 Replace the screws on each side of the control console 11 Replace the bezels using the 2 screws which attach to the valve brackets making note that there are front and rear bezels and will only attach properly in the correct location on the console 12 Push the Surface Knobs onto the valve stems 13 Replace the burner grate...

Page 16: ...l rating plate Line pressure testing above 1 2 psi 3 5 kPa gauge 14 35 6 cm WCP The cooktop and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa Line pressure testing at 1 2 psi 3 5 kPa gauge 14 35 6 cm WCP or lower The cooktop must be isolated from the gas supply piping sy...

Page 17: ...nobs and bezels 3 Remove the two screws on each side of the cooktop that hold the control console in place 4 Remove the console and set it aside 5 Locate the appropriate low turndown screw for the appropriate burner on the given valve The low turndown screw for the left rear right rear center rear and center front burner valves aluminum is located through the center of the valve stem The low turnd...

Page 18: ... Check that the control console is flush with the top edge of the cooktop 10 Replace the screws on each side of the control console 11 Replace the bezels using the 2 screws which attach to the valve brackets making note that there are front and rear bezels and will only attach properly in the correct location on the console 12 Push the Surface Knobs onto the valve stems 13 Replace the burner grate...

Reviews: