Product Dimensions

 * For non-vented (recirculating) installations
** For vented installations

Cabinet Dimensions

 * For non-vented (recirculating) installations

IMPORTANT:

Minimum distance “X”: 24" (61.0 cm) from 

electric cooking surface. 

Minimum distance “X”: 27" (68.6 cm) from 

gas cooking surfaces. 

Suggested maximum distance “X”: 36" (91.4 cm)

The chimneys can be adjusted for different ceiling heights. See 

the following chart.

Vented Installations

Min. ceiling height

Max. ceiling height

Electric cooking 

surface

7' 5" (2.26 m)

9' 2" (2.79 m)

Gas cooking 

surface

7' 8" (2.34 m)

9' 2" (2.79 m)

Non-vented (recirculating) Installations

Min. ceiling height

Max. ceiling height

Electric cooking 

surface

7' 5" (2.26 m)

9' 6" (2.9 m)

Gas cooking 

surface

7' 8" (2.34 m)

9' 6" (2.9 m)

NOTE:

 The range hood chimneys are adjustable and designed to 

meet varying ceiling or soffit heights, depending on the distance 

“X” between the bottom of the range hood and the cooking 

surface. For higher ceilings, a Stainless Steel Chimney Extension 

Kit Part Number W10337357 is available from your dealer or an 

authorized parts distributor. The chimney extension replaces the 

upper chimney shipped with the range hood.

Venting Requirements

(venting models only)

 

Vent system must terminate to the outdoors, except for non-

vented (recirculating) installations.

 

Do not terminate the vent system in an attic or other 

enclosed area.

 

Do not use 4" (10.2 cm) laundry-type wall cap.

 

Use metal vent only. Rigid metal vent is recommended. 

Plastic or metal foil vent is not recommended.

 

The length of vent system and number of elbows should be 

kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

 

Use no more than three 90° elbows.

 

Make sure there is a minimum of 24" (61 cm) of straight vent 

between the elbows if more than 1 elbow is used.

 

Do not install 2 elbows together.

 

Use clamps to seal all joints in the vent system.

 

The vent system must have a damper. If the roof or wall 

cap has a damper, do not use the damper supplied with the 

range hood.

 

Use caulking to seal exterior wall or roof opening around the 

cap.

 

The size of the vent should be uniform.

Cold Weather Installations:

An additional backdraft damper should be installed to minimize 

backward cold air flow and a thermal break should be installed 

to minimize conduction of outside temperatures as part of the 

vent system. The damper should be on the cold air side of the 

thermal break.
The break should be as close as possible to where the vent 

system enters the heated portion of the house.

Makeup Air:

Local building codes may require the use of makeup air systems 

when using ventilation systems greater than specified CFM of 

air movement. The specified CFM varies from locale to locale. 

Consult your HVAC professional for specific requirements in 

your area.

10" 

(25.4 cm)

20" (50.8 cm)

14

¹⁄₈

(35.9 cm)

7

¹⁄₄

(18.3 cm)

8

¹⁄₈

(20.7 cm)

*28

⁷⁄₈

" (72.6 cm) min.

 42

¹⁄₁₆

" (106.9 cm) max.

**28

³⁄₈

" (72.0 cm) min.

   38" (96.6 cm) max.

1

¹₂

" (4.0 cm)

30" (76.2 cm) or

36" (91.4 cm)

7

¹⁄₄

" (18.4 cm)

6⁵⁄₈

" (16.8 cm)

2" (5.1 cm) min.

6" (15.2 cm) min.*

Centerline

Side

cabinet

Side

cabinet

Vent and power

supply cable

entry location

Cooking surface

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15" (38.1 cm)

7

³⁄₈

" (18.8 cm)

“X”

bottom of 

canopy 

to cooking 

surface

30" (76.2 cm) or

36" (91.4 cm)

Summary of Contents for KVWB400DSS4

Page 1: ...isit our website at www kitchenaid ca HOTTE DE CUISINIÈRE CONFIGURÉE EN ÎLOT À MONTAGE MURAL 30 76 2 CM ET 36 91 4 CM Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composez le 1 800 807 6777 ou visitez notre site web à www kitchenaid ca Table of Contents Table des matières 2 LI3ZBD W10674121E IMPORTANT READ AND SAVE THESE INSTRU...

Page 2: ...ontains one or more chemicals known to the State of California to cause birth defects or other reproductive harm RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complet...

Page 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Page 4: ...orx T20 adapter Location Requirements IMPORTANT Observe all governing codes and ordinances Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located inside the range hood on the rear wall of the range hood Canopy hood location should be away from ...

Page 5: ... not recommended The length of vent system and number of elbows should be kept to a minimum to provide efficient performance For the most efficient and quiet operation Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than 1 elbow is used Do not install 2 elbows together Use clamps to seal all joints in the vent system The vent sy...

Page 6: ...formance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A copy of the above code standards can be obtained from National ...

Page 7: ...g upper and lower vent cover assembly 1 Position vent cover bracket on wall about 1 8 3 0 mm away from the ceiling 2 Mark the hole locations 3 Drill 2 3 8 9 5 mm holes for 8 x 40 mm wall anchors and insert anchors flush with the wall 4 Attach vent cover support bracket to wall Complete Preparation 1 Determine and make all necessary cuts in the wall for the vent system Install the vent system befor...

Page 8: ...ating installation only 1 Assemble the air deflector with the duct cover bracket with 2 assembly screws provided with the Recirculation Kit 2 Measure from the bottom of the air deflector to the bottom of the hood outlet 3 Cut the duct to the measured size X 4 Remove the air deflector 5 Slide the duct onto the bottom of the air deflector 6 Place the assembled air deflector and duct over the exhaust...

Page 9: ...n onto hood and lift upper cover to ceiling and install with 2 2 9 x 6 5 mm screws NOTE For vented installations the upper vent cover may be reversed to hide slots Complete Installation 1 For non vented recirculating installations only install charcoal filters over grille on blower housing See the Range Hood Care section 2 Install metal filters See the Range Hood Care section 3 Check the operation...

Page 10: ...Speed buttons C D and E set the desired speed and control the sound level for quiet operation The speed can be changed anytime during fan operation by pressing the desired blower speed button 1 To turn the blower on press the blower On Off button B and the desired speed button C D or E 2 To turn the blower off press the blower On Off button B Any of the 3 blower speed buttons can be in the on posi...

Page 11: ... by making sure the spring release handles are toward the front Insert aluminum filter into upper track 5 Push in spring release handle 6 Push up on metal filter and release handle to latch into place 7 Repeat steps 1 5 for the other filter 8 Close the stainless steel panel Engage the 2 pins in the spring catches to secure Non Vented Recirculating Installation Filters The charcoal filter is not wa...

Page 12: ... BK WH YL GN BK WH BR BU YL WH RD BK YL WH RD BK BU WH RD BK WH RD BK YL BK BU BR BK RD BU WH WH BK LED BK RD BK LED PUSH BUTTON SWITCH OPERATION FUNCTION OFF LAMPS LOW SPEED MED SPEED HIGH SPEED POSITION NO CONNECTION BROWN YELLOW 1 3 BROWN WHITE 1 4 BROWN RED 1 5 BROWN BLACK 1 6 MOTOR SPECIFICATIONS MOTOR RESISTANCE Ω POWER SUPPLY FREQUENCY POWER ABSORTION 120 VAC 60 Hz 240 W BLUE BLACK BLUE GRE...

Page 13: ...need further assistance you can write to KitchenAid with any questions or concerns at KitchenAid Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Canada Call the Whirlpool Canada LP Customer eXperience Centre toll free 1 800 807 6777 or visit our website at www kitchenaid ca Our Consultants ...

Page 14: ...ation solutions etc 5 Defects or damage caused by the use of non genuine KitchenAid parts or accessories 6 Conversion of products from natural gas or L P gas 7 Damage from accident misuse abuse fire floods acts of God or use with products not approved by KitchenAid 8 Repairs to parts or systems to correct product damage or defects caused by unauthorized service alteration or modification of the ap...

Page 15: ...areil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d autres Tous les messages de sécurité suivront le symbole d alerte de sécurité et le mot DANGER ou AVERTISSEMENT Ces mots signifien...

Page 16: ...W10674121E 2016 KitchenAid Used under license in Canada All rights reserved Utilisé sous licence au Canada Tous droits réservés 11 16 ...

Reviews: