KitchenAid KICU265H Dimension Manual Download Page 1

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

CABINET OPENING DIMENSIONS

VENTING REQUIREMENTS

KICU265H
KICU285H

Electrical:

120-volt, 60-Hz, AC-only, 15-amp.

electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit is
recommended.

36" and 48" Island Canopy Range Hood

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. 4360369 Rev. C

10-15-02

®

8’ (2.4 m) min. - 
9’ (2.7 m) max.
ceiling to floor

support
structure

24" (61 cm) min.
bottom of canopy to
cooking surface

canopy

lower
chimney

upper
chimney

36" (91.4 cm)
base cabinet
height

3-1/4" x 10"
(8.3 cm x 25 cm)
through 
the roof

roof cap

Horizontal wall venting

3-1/4" x 10"
(8.3 cm x 25 cm)
through the wall 

wall cap

Vertical roof venting

The vent system length should not
exceed the lengths shown in the
chart below.

Vent size

Maximum length

3-1/4" x 10"

35 ft. (10.7 m)

(8.3 cm x 25 cm)

7" (17.8 cm) round

40 ft. (12.2 m)

8" (20.3 cm) round

50 ft. (15.2 m)

9" (22.9 cm) round

60 ft. (18.3 m)

Vent Piece 

3-1/4" x 10" (8.3 cm x 25 cm) 7" (17.8 cm), 8" (20.3 cm)

Rectangular

or 9" (22.9 cm) Round 

45° elbow

7.0 feet

2.5 feet

(2.1 m)

(0.8 cm)

90° elbow

5.0 feet

5.0 feet

(1.5 m)

(1.5 m)

90° flat elbow 

12.0 feet

(3.7 m)

transition to round

5.0 feet

(1.5 m)

wall cap

0.0 feet

(0.0 m)

3-1/4" x 10”
(8.3 cm x 25 cm)
elbow

wall
cap

Maximum length  

= 35 ft. (10.7 m)

1 — 90° elbow 

=  5 ft. (1.5 m)

8 ft. (2.4 m) straight  =  8 ft. (2.4 m)
1 — wall cap 

=  0 ft. (0 m)

Length of 3-1/4" x 10"
(8.3 cm x 25 cm)
system 

= 13 ft. (4 m)

6 ft. (1.8 m)

2 ft.

(0.6 m)

3-1/4" x 10" (8.3 cm x 25 cm)

vent system

To calculate the length of the system you need, add the
equivalent feet for each vent piece used in the system.

Note: Flexible vent is Not
recommended.

If it is used, each foot of flexible vent
used is equivalent to two feet (61 cm)
of straight metal vent when
calculating the vent system length.
(Example: A flexible elbow equals two
standard elbows.)

36" hood  35-3/8" (89.9 cm) or
48" hood  47-1/4" (120 cm)
overall width

23-5/8" (60 cm)
overall depth

24-5/8" (62.5 cm) min. -
34-3/4" (88.3 cm) max.
overall chimney height

23-5/8"
(60 cm)
lower
chimney
height

1" (2.5 cm) min. - 
11-1/8" (23.8 cm) max.
upper chimney height

10-1/4" (26 cm)
canopy height

7 1/16" 

(17.9 cm)

10 7/8" 

(27.6 cm)

Note: 3-1/4" x 10" 
(8.3 cm x 25 cm)
rectangular vent must
be used inside chimney
cover. Round vent will
not fit inside chimney
cover.

Note: 3-1/4" x 10" 
(8.3 cm x 25 cm)
rectangular vent must
be used inside chimney
cover. Round vent will
not fit inside chimney
cover.