Category II2H3+
Electric Power: 230 V - 50 Hz
If a hood is to be installed above the hob, refer to the hood
installation instructions to ensure the correct height above
the hob.
Hood and cabinetry clearances (mm)
Injector table
6
Type of gas used
Type of
burner
Injector
label
Control
primary air
(X)(mm)
Nominal
heat flow
kW
Nominal
consumption
Reduced
heat flow
kW
Gas pressure (mbar)
min.
nom.
max.
NATURAL GAS
(Methane) G20
wok
fast
semi-fast
auxiliary
145
128
95
78
6
-
-
-
4,20
3,00
1,65
1,00
400 l/h
286 l/h
157 l/h
95 l/h
1,40
0,90
0,40
0,30
17
20
25
LIQUID
PETROLEUM
GAS (Butane)
G30
wok
fast
semi-fast
auxiliary
100
85
65
50
11
-
-
-
4,20
3,00
1,65
1,00
305 g/h
218 g/h
120 g/h
73 g/h
1,40
0,90
0,40
0,30
20
28-30
35
LIQUID
PETROLEUM
GAS (Propane)
G31
wok
fast
semi-fast
auxiliary
100
85
65
50
11
-
-
-
4,20
3,00
1,65
1,00
300 g/h
214 g/h
118 g/h
71 g/h
1,40
0,90
0,35
0,30
25
37
45
Type of gas used
Configuration model
Nominal heat flow kW
Overall nominal
consumption
Required air (m
3
) for
the combustion 1 m
3
of
gas
G20 20 mbar
5 burners
11,50
1090 l/h
9,52
G30 28-30 mbar
5 burners
11,50
836 g/h
30,94
G31 37 mbar
5 burners
11,50
821 g/h
23,80