background image

Electrical

requirements

D.

Provide a gas supply line of 3/4" 

rigid pipe to the cooktop location. A
smaller size pipe on long runs may result
in insufficient gas supply. Pipe-joint
compounds, suitable for use with L.P. gas,
must be used. With L.P. gas, piping or
tubing size can be 1/2" minimum. L.P. gas
suppliers usually determine the size and
materials used on the system.

L.P. Gas:

No attempt shall be made to convert the
cooktop from the gas specified on the
model/serial rating plate for use with a
different gas without consulting the
serving gas supplier. Conversion must be
done by a qualified service technician. To
convert to L.P. gas, use L.P. gas
conversion kit part no. 4455218. The parts
for this kit are in the literature package
supplied with cooktop.

E.

If local codes permit, use a flexible

stainless steel tubing gas connector,
design-certified by AGA or CSA
International, to connect the cooktop to
the rigid gas supply line. 5/8" diameter line
is recommended. Do Not kink or damage
the flexible connector when moving the
cooktop. The pressure regulator has 1/2"
female pipe threads. You will need to
determine the fittings required, depending
on the size of your gas supply line, flexible
metal connector and shutoff valve.

F.

The supply line shall be equipped

with an approved shutoff valve. This valve
should be located in the same room as
the cooktop and should be in a location
that allows ease of opening and closing.
Do Not block access to the shutoff valve.
The valve is for turning on or shutting off
gas to the appliance.

to cooktop

shutoff valve
“open” position

gas supply
line

G.

If rigid pipe

is used as a gas 
supply line, a combination of pipe
fittings must be used to obtain an in-line
connection to the cooktop. All strains
must be removed from the supply and
fuel lines so cooktop will be level and in
line.

H.

The regulator must be checked at a

minimum 1-inch (2.5 cm) water column
above the set pressure. The inlet pressure to
the regulator should be as follows for
operation and checking the regulator setting:

NATURAL GAS:
Set pressure 5 inches (12.7 cm) W.C.
Supply pressure 7-14 inches (17.8 cm
to 35.5 cm) W.C. maximum.

L.P. GAS:
Minimum pressure 10 inches (25.4 cm)
W.C.
Supply pressure 14 inches (35.5 cm)
W.C.

I.

Line pressure testing:

Testing above 1/2 psi (3.5 kPa) or
14 inches (35.6 cm) W.C. (gauge)
The cooktop and its individual shutoff
valve must be disconnected from the gas
supply piping system during any pressure
testing of that system at test pressures
greater than 1/2 psig (3.5kPa).

Testing below 1/2 psi (3.5 kPa) or
14 inches (35.6 cm) W.C. (gauge) or
lower
The cooktop must be isolated from the
gas supply piping system by closing its
individual manual shutoff valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less
than 1/2 psig (3.5 kPa).

Electrical Shock Hazard

Plug into a grounded 3-prong
outlet.

Do not remove ground prong.

Do not use an adapter.

Failure to follow these
instructions can result in death,
fire, or electrical shock.

WARNING

A 120-volt, 60-Hz, AC-only, 15-ampere,
fused electrical supply is required. A
time-delay fuse or circuit breaker is
recommended. It is recommended that a
separate circuit serving only this
appliance be provided.

Electronic ignition systems operate within
wide voltage limits, but proper ground and
polarity are necessary. In addition to
checking that the outlet provides 120-volt
power and is correctly grounded, the
outlet must be checked by a qualified
electrician to see if it is wired with correct
polarity. A wiring diagram is provided on
the last page of these instructions.

Important: This cooktop is equipped with
an electronic ignition system that will not
operate if plugged into an outlet that is
not properly polarized.

This appliance, when installed, must be
electrically grounded in accordance with
local codes or, in the absence of local
codes, with the current CSA standard
C22.1. Canadian Electrical Code Part 1*.

Recommended ground method

For your personal safety, this cooktop
must be grounded. This cooktop is
equipped with a 3-prong ground plug. To
minimize possible shock hazard, the cord
must be plugged into a mating 3-prong
ground-type outlet, grounded in
accordance with the National Electrical
Code ANSI/NFPA 70 latest edition** or
Canadian Electrical Code (CSA)* — and
local codes and ordinances. If a mating
outlet is not available, it is the personal
responsibility and obligation of the
customer to have a properly polarized
and grounded, 3-prong outlet installed by
a qualified electrician.

If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.

Copies of the standards listed above may be
obtained from:

*

CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575

**

National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269

3-prong polarized
ground-type outlet

power
supply cord

3-prong 
ground plug

ground
prong

6

Check with a qualified electrician if
you are not sure whether the cooktop
is properly grounded.

Do Not ground to a gas pipe.

Summary of Contents for KGCP467HSS0

Page 1: ...ing cooktop Both numbers are on the model serial rating plate located on the underside of the cooktop burner box Model ___________________________ Serial ___________________________ Questions regarding features operation performance parts or service Call 1 800 422 1230 or visit our web site at www kitchenaid com IMPORTANT Read and save these instructions 36 91 4 cm Professional Gas Cooktop for res...

Page 2: ...rances specified on the model serial rating plate The model serial rating plate can be found on the underside of the cooktop burner box It is recommended that an overhead vent hood be used with this cooktop For island installations a 48 122 cm hood is recommended Check location where cooktop will be installed The location should be away from strong draft areas such as windows doors and strong heat...

Page 3: ... 8 18 1 cm 7 8 22 2 mm 2 3 16 55 6 mm 1 3 16 30 1 mm side view of cooktop gas inlet is located 1 7 8 4 8 cm from back of burner box and 4 7 8 11 7 cm in from L H side of burner box 9 22 9 cm 26 1 4 66 7 cm 36 91 4 cm long 3 prong ground type power supply cord backguard shown or island trim see P 4 and 7 22 55 9 cm ...

Page 4: ... 1 25 4 mm clearance to the back wall use the optional stainless steel island trim included with the cooktop to cover the backguard mounting flanges Provide an 8 x 8 20 3 cm x 20 3 cm cutout in left rear corner of cutout enclosure to provide clearance for gas inlet power supply cord and to allow the rating label to be visible Copies of the standards listed may be obtained from National Fire Protec...

Page 5: ...rican National Standard National Fuel Gas Code ANSI Z223 1 latest edition or CANI B149 1 or 2 Explosion Hazard Use a new AGA or CSA approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 water column Examples of a qualified person include licensed heating personnel authorized gas co...

Page 6: ...t system at test pressures greater than 1 2 psig 3 5kPa Testing below 1 2 psi 3 5 kPa or 14 inches 35 6 cm W C gauge or lower The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Electrical Shock Hazard Plug into a grounded 3 ...

Page 7: ...ill need to determine the fittings required depending on your installation 7 Attach the backguard or island trim as required for your installation Attachment screws are in the literature package 8 Place cooktop completely into cutout Note The cooktop must be level for best cooking performance 9 If the pressure regulator and flexible stainless steel gas supply were not assembled in Step 3 complete ...

Page 8: ...ompany Maintenance If removing the cooktop is necessary for maintenance shut off gas supply Disconnect the gas and electric supply After disconnecting the gas and electric supply finish removing the cooktop Generally the cooktop does not need to be removed for servicing 8 16 Push in and turn each control knob to the LO or simmer setting The LO setting of each burner has been factory set to the low...

Page 9: ...S Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing BLK BLK PLUG LINE 1 4 WIDE BLADE GROUND CONNECT 250 TERMINALS GROUND SPARK MODULE 120 VAC 60 Hz 1 PHASE 15 AMP VALVE SWITCHES IGNITOR ELECTRODES ROUND BLADE Part No 4455046 Rev A 2000 KitchenAid Registered Trademark Trademark of K...

Reviews: