Summary of Contents for KEYS750LQ2

Page 1: ...acuation 21 Installation des pieds de nivellement 22 Raccordement du conduit d _vacuation 22 Mise h niveau de la s_cheuse 22 Inversion de I ouverture de la porte facultatif 22 Achever I installation 23 DRYER SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages Thi...

Page 2: ...6 cm above the floor for a garage installation Failure to do so can result in death explosion or fire You will need A location that allows for proper exhaust installation See Venting Requirements Aseparate30 amp circuit If using a power supply cord a grounded electrical outlet located within 2 ft 61 cm of either side of the dryer See Electrical Requirements U S A or Electrical Requirements Canada ...

Page 3: ...r are required Louvered doors with equivalent ventilation openings are acceptable Companion appliance spacing should also be considered __H LI_I 1_ max 45 7 o _t_ 2g _ _o _o F 2_4 Hs 2 0cm 73 66crn 0cm 0crn 70 5crn 14cm A B 48in 310 crn2 24in 2 155cm 2 _ 6 cm 1 3 7 6 cm A Recessed area B Side view closet or confined area C Closet door with vents Additional spacing recommended Mobile Home Additiona...

Page 4: ...ctors If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should contain A UL listed 30 amp power supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends A UL listed strain relief If your o...

Page 5: ...ptacle 14 30R If you are using a replacement power supply cord it is recommended that you use Power Supply Cord Replacement Part Number 3394208 For further information please reference the service numbers located in the Dryer User Instructions GROUNDING iNSTRUCTiONS For a grounded cord connected dryer This dryer must be grounded In the event of malfunction or breakdown grounding will reduce the ri...

Page 6: ...r Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock 1 Disconnect power 2 Remove the hold down screw and terminal block cover A B C D A Terminalblock cover B Externalground conductor screw C Center silver colored terminal block screw D Hold down screw location E Neutral ground wire...

Page 7: ...mplete installation following instructions for your type of electrical connection 4 wire recommended 3 wire if 4 wire is not available Electrical Connection Options If your home has And you will be Go to Section connecting to 4 wire receptacle A UL listed 4 wire connection NEMA Type 14 30R 120 240 volt Power supply cord _ _ minimum 30 amp dryer power supply cord 4 wire direct A fused 4 wire connec...

Page 8: ...E A External ground conductor screw B Center silver colored terminal block screw C Neutral wire white or center wire D 3_ 1 9 cm UL listed strain relief E Neutral ground wire F Ground wire green or bare of power supply cord 4 Connect the other wires to outer terminal block screws Tighten screws 5 Tighten strain relief screws 6 Insert tab of terminal block cover into slot of dryer rear panel Secure...

Page 9: ...sen or remove center silver colored terminal block screw Connect neutral wire white or center wire of power supply cord to the center silver colored terminal screw of the terminal block Tighten screw E A Neutral ground wire B External ground conductor screw C Center silver colored terminal block screw D Neutral wire white or center wire E _ 1 9 cm UL ilsted strain relief 3 Connect the other wires ...

Page 10: ...uirements Optional 3 wire connection Use for direct wire or power supply cord where local codes do not permit connecting cabinet ground conductor to neutral wire 1 Remove center silver colored terminal block screw 2 Remove neutral ground wire from external ground conductor screw Connect neutral ground wire and the neutral wire white or center wire of power supply cord cable under center silver col...

Page 11: ...mmended 4 10 2cm heavymetal exhaust vent DURASAFF Mvent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories For more information see the Assistance or Service section of the Dryer User Instructions Rigid metal vent For best drying performance rigid metal vents are recommended Rigid metal vent is recommended to avoid crushing and kinking Flexible metal vent Flex...

Page 12: ...t outlet Standard exhaust installation with rigid metal or flexible metal vent Alternate installations for close clearances Venting systems come in many varieties Select the type best for your installation Two close clearance installations are shown Refer to the manufacturer s instructions r r i B A Over the top installation also available with one offset elbow B Periscope installation NOTE The fo...

Page 13: ...ble metal 27 ft 8 2 m 19 ft 5 8 m 3 Rigid metal 35 ft 10 7 m 29 ft 8 8 m Flexible metal 25 ft 7 6 m 17 ft 5 2 m 4 Rigid metal 27 ft 8 2 m 21 ft 6 4 m Flexible metal 23 ft 7 m 15 ft 4 6 m 1 Install exhaust hood Use caulking compound to seal exterior wall opening around exhaust hood 2 Connect vent to exhaust hood Vent must fit inside exhaust hood Secure vent to exhaust hood with 4 10 2 cm clamp 3 Ru...

Page 14: ...esired Reversible Large Side Swing Door C 1 Place towel A on top of dryer to protect surface 2 Open dryer door Remove bottom screws from cabinet side of hinges C Loosen do not remove top screws from cabinet side of hinges 3 Lift door until top screws in cabinet are in large part of hinge slot Pull door forward off screws Set door on top of dryer Remove top screws from cabinet 4 Use a small flat bl...

Page 15: ...rect wire installation turn on power In Canada Electrical Shock Hazard Plug into a grounded 4 prong outlet Failure to do so can result in death or electrical shock 7 8 9 10 Plug into a grounded 4 prong outlet Turn on power Remove the blue protective film on the console and any tape remaining on the dryer Read Dryer Use in the Dryer User Instructions Wipe the dryer drum interior thoroughly with a d...

Page 16: ...s outils et pieces necessaires avant de commencer I installation Lire et suivre les instructions foumies avec les outils indiques ici Tournevis h lame plate Tournevis Phillips n 2 Cle a molette avec ouverture jusqu a 1 2 54 cm ou cle douille hexagonale pour ajuster les pieds de la secheuse Clapets d evacuation Cisaille de ferblantier pour I installation d un nouveau conduit Pistolet h calfeutrage ...

Page 17: ...t pas I installation des secheuses dans un garage un placard une maison mobile ou une chambre a coucher Communiquer avec I inspecteur des b timents local D_gagements de s_paration a respecter L emplacement dolt 6tre assez grand pour permettre d ouvrir completement la porte de la secheuse Dimensions de la s_cheuse 151 4 43 __ 38 74cm 110cm _ _ t_ I_ 13 70 5e 433A 110crn 27a 4 qk 223A 73 66 m B 223 ...

Page 18: ...fusible temporise ou disjoncteur On recommande egalement que cet appareil soit alimente par un circuit independant Cette secheuse est equip6e d un cordon electrique homologue par la CSA International a introduire dans une prise murale standard 14 30R Le cordon mesure 5 pi 1 52 m Veiller ce que la prise murale se trouve a proximite de I emplacement definitif de la secheuse Prise murale a 4 fils 14 ...

Page 19: ...duit d _vacuation en metal Iourd de 4 10 2 crn On peut se procurer les produits d evacuation DURASAFF M aupres du marchand ou en telephonant a Pieces et accessoires Whirlpool Pour plus de renseignements voir la section Assistance ou service dans les Instructions pour I utilisateur de la secheuse Conduit m_tallique rigide Pour un meilleur rendement de sechage on recommande d utiliser des conduits m...

Page 20: ...cheuse B Coude C Mur D Clapet de d_charge E Brides F Conduit m_tallique rigide ou souple G Longueur deconduit n_cessaire pour raccorder es coudes H Bouche de d_charge Installations standard du conduit d 6vacuation a raide d un conduit m_tallique rigide ou souple Autres installations o_Jle d_gagement est r_duit II existe de nombreux types de systemes d evacuation Choisir le type qui convient le mie...

Page 21: ...les exigences d evacuation qui vous aideront a atteindre la meilleure performance de sechage Tableau des syst_mes d _vacuation REMARQUE Les installations d evacuation du conduit par le c6te ou par le bas comportent un changement de direction a 90 I interieur de la secheuse Pour etablir la Iongueur maximale du conduit ajouter un changement de direction a 90 au tableau Nombre de Type de Clapets de C...

Page 22: ... ou ecras 4 Une fois que le conduit d evacuation est raccorde retirer les cornieres et le carton Contr61er I aplomb de la secheuse Contr61er I aplomb tout d abord transversalement puis dans le sens avant arriere Si la secheuse n est pas de niveau la deposer sur un bloc de bois Utiliser une cle a molette pour ajuster les pieds vers le haut ou vers le bas et v ifier a nouveau si elle est de niveau _...

Page 23: ...c6te gauche de la caisse Inserer les bouchons dans les trous de charniere du c6te droit de la caisse 9 Inserer les vis dans les trous inferieurs du c6te gauche de la caisse Serrer les visa moiti Placer la porte de telle sorte que la partie elargie du trou de charniere se trouve au dessus des vis Glisser la porte vers le haut de telle sorte que les vis se trouvent au bas des fentes Serrer les vis I...

Page 24: ...r s il y a de la chaleur En cas de chaleur annuler le programme et fermer la porte Si aucune chaleur n est perceptible d_sactiver la s_cheuse et v_rifier ce qui suit II peut y avoir 2 fusibles ou disjoncteurs pour la secheuse V ifier que les 2 fusibles sont intacts et serres ou que les deux disjoncteurs ne se sont pas declenches S il n y a toujours pas de chaleur contacter un technicien qualifi RE...