INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Tools needed

Phillips screwdriver

Drill

1

³⁄₈

" (3.5 cm) hole saw

Parts supplied

4 - #8-18 x 

⁵⁄₈

" screws

Lens (for panel ready models)

Check local codes. Check existing electrical supply. See 
“Electrical Requirements.”

It is recommended that all electrical connections be made by a 
licensed, qualified electrical installer.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Cutout dimensions that are shown must be used. Given 
dimensions provide minimum clearance with warming drawer.

Recessed installation area must provide complete enclosure 
around the recessed portion of the warming drawer. 

Grounded electrical supply is required. See “Electrical 
Requirements” section.

Electrical supply outlet should be located in the rear wall on 
the upper right-hand side of the cutout or in an adjacent 
cabinet. The outlet must be recessed. If the electrical outlet is 
located in an adjacent cabinet, a 1

³⁄₈

" (3.5 cm) minimum 

diameter hole should have been drilled in the back of the 
cutout or support surface to pass the power supply cord 
through to the outlet.

Warming drawer support surface must be solid, level and 
flush with bottom of cabinet cutout.

For best performance results, make sure the warming drawer is 
leveled before completing installation. There is no way to level the 
warming drawer after it has been installed. If the installation is not 
level, the door may slide open or not seal tightly, allowing heat to 
escape.

NOTE: If installing the warming drawer below another product, 
refer to that product’s literature for any installation requirements.

Product Dimensions

Cabinet Dimensions

Cabinet Side View

WARMING 
DRAWER 
SIZE

OVERALL
WIDTH (A) 

RECESSED
WIDTH (B)

RECESSED
HEIGHT (C)

24" (61 cm)

23

³⁄₄

" (60.3 cm)

22

¹⁄₄

" (56.5 cm)

9" (22.9 cm)

27" (68.6 cm)

26

³⁄₄

" (67.9 cm)

25

¹⁄₄

" (64.1 cm)

9" (22.9 cm)

30" (76.2 cm)

29

³⁄₄

" (75.6 cm)

28

¹⁄₄

" (71.8 cm)

9" (22.9 cm)

A

B

C

Warming
drawer
front

Support surface must be
solid, level, flush with
bottom of cabinet cutout.

22

³⁄₄

"

(57.8 cm)
recessed

oven depth

24"

(61 cm)

min. cutout

depth

Summary of Contents for KEWS105BSS

Page 1: ...LLATION 8 Installation du tiroir réchaud 8 Achever l installation 8 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others...

Page 2: ...acent cabinet The outlet must be recessed If the electrical outlet is located in an adjacent cabinet a 1 3 5 cm minimum diameter hole should have been drilled in the back of the cutout or support surface to pass the power supply cord through to the outlet Warming drawer support surface must be solid level and flush with bottom of cabinet cutout For best performance results make sure the warming dr...

Page 3: ...he above code standards can be obtained from National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this warming drawer be ...

Page 4: ...are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 For warming drawer use and cleaning read the Use and Care Guide 5 Turn the Temperature control knob to HI The light should illuminate If warming drawer s does not operate check the following Household fuse is inta...

Page 5: ... non respect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiels de ...

Page 6: ...it être encastrée Si la prise électrique est située dans un placard adjacent un trou de diamètre 1 3 5 cm minimum doit avoir été percé à l arrière de l ouverture ou de la surface de support pour faire passer le cordon d alimentation La surface de support du tiroir réchaud doit être robuste horizontale et en affleurement avec le bas de l ouverture découpée dans le placard Pour le meilleur rendement...

Page 7: ... de la liaison à la terre Pour obtenir un exemplaire de la norme des codes ci dessus contacter National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 L appareil doit être alimenté par un circuit de 120 V CA seulement 60 Hz 15 ampères protégé par fusible On recommande également d utiliser un fusible ou u...

Page 8: ...découvrir laquelle aurait été oubliée 2 Vérifier la présence de tous les outils 3 Jeter recycler tous les matériaux d emballage 4 Pour l utilisation et le nettoyage du tiroir réchaud lire le Guide d utilisation et d entretien 5 Tourner le bouton de commande de la température à HI élevée le témoin devrait s allumer Si le s tiroir s réchaud s ne fonctionne nt pas contrôler ce qui suit Les fusibles d...

Reviews: