background image

4

Electrical Requirements

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.

Check with a qualified electrical installer if you are not sure the 
oven is properly grounded.

This oven must be connected to a grounded metal, permanent 
wiring system.

Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22.1-94, Canadian 
Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and 
all local codes and ordinances.

A copy of the above code standards can be obtained from:

National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471

CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575

Electrical Connection

To properly install your oven, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.

Oven must be connected to the proper electrical voltage, 
amperage, and frequency as specified on the model/serial 
number rating plate. See the following illustration.

Models rated from 7.3 to 9.6 kW at 240 volts (5.4 to 7.4 kW at 
208 volts) require a separate 40-amp circuit. Models rated at 
4.8 kW and below at 240 volts (3.6 kW and below at 
208 volts) require a separate 20-amp circuit.

A circuit breaker is recommended.

Connect directly to the fused disconnect (or circuit breaker 
box) through flexible, armored or nonmetallic sheathed, 
copper cable (with grounding wire). See “Make Electrical 
Connection” section. 

Flexible conduit from the oven should be connected directly 
to the junction box.

Do not cut the conduit. The length of conduit provided is for 
serviceability of the oven.

A UL listed or CSA approved conduit connector must be 
provided.

If the house has aluminum wiring, follow the procedure 
below:

1. Connect a section of solid copper wire to the ends of the 

flexible conduit leads.

2. Connect the aluminum wiring to the added section of 

copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.

For power requirements, refer to the following table.

*L1 includes both the microwave and the oven, and L2 includes 

only the oven. Amperage values noted above are for information 
purposes only: the units are rated in watts.

A. Model/serial number plate

A

Model

Voltage

Amperage 
(L1)*

Amperage 
(L2)*

Rating 
(kW)

MMW9730

120/240

129/208

30

28

15

15

7.2

5.9

WOC54EC0, 
WOC95EC0

120/240

120/208

30

28

15

15

7.2

5.9

WOC54EC7

120/240

120/208

30

28

15

15

7.2

5.9

KEMS309

120/240

120/208

33

31

15

15

8.0

6.6

Summary of Contents for KEMS309BSP

Page 1: ...lector Kit only for ovens installed above warming drawers 7 Complete Installation 8 SÉCURITÉ DU FOUR À MICRO ONDES ET DU FOUR CONVENTIONNEL COMBINÉS ET ENCASTRÉS 9 EXIGENCES D INSTALLATION 9 Outils et pièces 9 Exigences d emplacement de l ensemble four à micro ondes et four conventionnel encastrés 9 Spécifications électriques 11 INSTRUCTIONS D INSTALLATION 11 Préparation de l ensemble des fours en...

Page 2: ...e complete enclosure around the recessed portion of the oven Grounded electrical supply is required See Electrical Requirements section Electrical supply junction box should be located 3 7 6 cm maximum below the support surface when the oven is installed in a wall cabinet A 1 2 5 cm minimum diameter hole should have been drilled in the left rear corner of the support surface to pass the appliance ...

Page 3: ... 27 68 6 cm models A 27 68 6 cm min cabinet width B 1 2 5 cm top of cutout to bottom of upper cabinet door C 19 48 9 cm bottom of cutout to floor is recommended 4 19 10 2 48 9 cm bottom of cutout to floor is acceptable D 25 64 8 cm cutout width E 1 3 8 cm min bottom of cutout to top of cabinet door F 41 105 cm recommended cutout height G 24 60 7 cm cutout depth 30 76 2 cm models A 30 76 2 cm min c...

Page 4: ...dels rated at 4 8 kW and below at 240 volts 3 6 kW and below at 208 volts require a separate 20 amp circuit A circuit breaker is recommended Connect directly to the fused disconnect or circuit breaker box through flexible armored or nonmetallic sheathed copper cable with grounding wire See Make Electrical Connection section Flexible conduit from the oven should be connected directly to the junctio...

Page 5: ...m wire This oven is manufactured with a neutral white power supply wire and a cabinet connected green or bare ground wire twisted together 1 Disconnect power 2 Feed the flexible conduit from the oven through the opening in the cabinet 3 Remove junction box cover if it is present 4 Install a UL listed or CSA approved conduit connector to the junction box 5 Route the flexible conduit from the oven t...

Page 6: ...tor 2 Connect the 2 white wires D and the green or bare ground wire of the oven cable using a UL listed wire connector 3 Connect the 2 red wires G together using a UL listed wire connector 4 Install junction box cover InstallOven 1 Using 2 or more people lift oven partially into cabinet cutout Use the oven opening as an area to grip NOTE Push against seal area of oven front frame when pushing oven...

Page 7: ...locked position 11 Check that door is free to open and close If it is not repeat the removal and installation procedures See Prepare Built In Microwave Oven Combination section 12 Reconnect power 13 Display panel will light briefly and PF should appear in the display 14 If display panel does not light please reference the Assistance or Service section of the Use and Care Guide or contact the deale...

Page 8: ...d contact a qualified technician 7 Press CANCEL OVEN Check Operation of Microwave Oven 1 Fill a microwave safe container with 1 cup 250 mL of water and place container inside microwave oven Close door firmly 2 Press COOK and set microwave oven cook time to 2 00 minutes 3 Press START The interior microwave oven light should be on and the remaining cooking time should be displayed When display reads...

Page 9: ...placementdel ensemble fouràmicro ondesetfourconventionnel encastrés IMPORTANT Observer les dispositions de tous les codes et règlements en vigueur Respecter les dimensions indiquées pour la cavité d installation entre les placards Ces dimensions prennent en compte les dégagements de séparation minimaux nécessaires L espace d installation doit permettre la formation d une enceinte complète autour d...

Page 10: ... encastrement 23 59 1 cm max E Largeur hors tout 27 68 6 cm Modèles de 30 76 2 cm A Hauteur hors tout 42 108 cm B Largeur d encastrement 28 72 3 cm C Hauteur d encastrement 41 104 1 cm D Profondeur d encastrement 23 59 1 cm max E Largeur hors tout 30 76 2 cm B A C D E Modèles de 27 68 6 cm A Largeur du placard 27 68 6 cm min B 1 2 5 cm entre le sommet de l ouverture et le bas de la porte du placar...

Page 11: ...t destinée à faciliter l entretien du four L installateur doit fournir un connecteur de conduit homologation UL ou CSA Si le domicile est équipé d un câblage en aluminium suivre les instructions suivantes 1 Connecter une section de câble en cuivre massif aux extrémités du conduit flexible 2 Connecter le câblage en aluminium à la section ajoutée de câblage en cuivre en utilisant des connecteurs et ...

Page 12: ...lectrique 2 Faire passer le conduit de câble flexible depuis le four à travers l ouverture dans le placard 3 Le cas échéant enlever le couvercle du boîtier de connexion 4 Installer un connecteur de conduit homologation UL ou CSA sur le boîtier de connexion 5 Acheminer le conduit de câble flexible depuis le four jusqu au boîtier de connexion utiliser un connecteur de conduit homologation UL ou CSA ...

Page 13: ...ion du domicile lorsque les codes locaux autorisent un tel raccordement 1 Connecter ensemble les 2 conducteurs noirs C avec un connecteur de fils homologation UL 2 Connecter les 2 conducteurs blancs D et le conducteur vert ou nu de liaison à la terre du câble du four avec un connecteur de fils homologation UL 3 Connecter ensemble les 2 conducteurs rouges G avec un connecteur de fils homologation U...

Page 14: ...e côté de l évent fixer solidement l évent au four 7 Réinstaller les grilles du four 8 Réinstaller la porte du four insérer les extrémités des charnières dans les ouvertures destinées à les recevoir sur le châssis du four 9 Enfoncer les charnières aussi loin qu elles peuvent aller et ouvrir la porte du four On doit percevoir le mouvement de la porte du four lorsqu elle se met en place 10 Faire piv...

Page 15: ...ycler tous les matériaux d emballage 4 Pour l utilisation et le nettoyage du four lire le Guide d utilisation et d entretien Vérification du fonctionnement du four inférieur 1 Mettre l appareil sous tension 2 À la première utilisation régler l horloge et toute autre préférence éventuelle si possible Consulter le Guide d utilisation et d entretien pour plus de renseignements 3 Appuyer sur BROIL cui...

Page 16: ...térieure du four à micro ondes devrait s éteindre 4 Appuyer sur START mise en marche Le four à micro ondes devrait commencer la cuisson et la lumière intérieure du four à micro ondes devrait être allumée Laisser le four à micro ondes terminer la durée de cuisson Un signal sonore retentira 4 fois à la fin de la durée de cuisson et le four à micro ondes s éteindra 5 Ouvrir la porte du four à micro o...