KitchenAid Built-In Microwave/Oven Combin Installation Instructions Manual Download Page 4

4

Water Supply Requirements

A cold water supply with water pressure between 30 and 120 psi 
(207 and 827 kPa) is required to operate the steam feature. In 
Massachusetts, plumbing code 248 CMR 3.00 and 10.00 must 
be followed. If you have questions about your water pressure call 
a licensed, qualified plumber.

Reverse Osmosis Water Supply

IMPORTANT: The pressure of the water supply coming out of a 
reverse osmosis system going to the water inlet valve of the oven 
needs to be between 30 and 120 psi (207 and 827 kPa).

If a reverse osmosis water filtration system is connected to your 
cold water supply, the water pressure to the reverse osmosis 
system needs to be a minimum of 40 psi (276 kPa).

If the water pressure to the reverse osmosis system is less than 
40 psi (276 kPa):

Check to see whether the sediment filter in the reverse 
osmosis system is blocked. Replace the filter if necessary.

Allow the storage tank on the reverse osmosis system to refill 
after heavy usage.

If you have questions about your water pressure, call a licensed, 
qualified plumber.

Electrical Requirements

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and the wire gauge are in accordance with local 
codes.

Check with a qualified electrical installer if you are not sure the 
oven is properly grounded.

This oven must be connected to a grounded metal, permanent 
wiring system.

Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22.1-94, Canadian 
Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and 
all local codes and ordinances.

A copy of the above code standards can be obtained from:

 National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

Electrical Connection

To properly install your oven, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.

Oven must be connected to the proper electrical voltage and 
frequency as specified on the model/serial number rating 
plate. The model/serial number rating plate is located at the 
bottom of the right-hand mounting rail. See the following 
illustration.

Models rated from 7.3 to 9.6 kW at 240 volts (5.5 to 7.2 kW 
at 208 volts) require a separate 50-amp circuit. Models rated 
at 7.2 kW and below at 240 volts (5.4 kW and below at 
208 volts) require a separate 30-amp circuit.

A circuit breaker is recommended.

Connect directly to the circuit breaker box (or fused 
disconnect) through flexible, armored or nonmetallic 
sheathed, copper cable (with grounding wire). See “Make 
Electrical Connection” section. 

Flexible conduit from the oven should be connected directly 
to the junction box.

Do not cut the conduit. The length of conduit provided is for 
serviceability of the oven.

A UL listed or CSA approved conduit connector must be 
provided.

If the house has aluminum wiring follow the procedure below:

1. Connect a section of solid copper wire to the pigtail 

leads.

2. Connect the aluminum wiring to the added section of 

copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.

A. Model/serial number plate

A

Summary of Contents for Built-In Microwave/Oven Combin

Page 1: ...cal Connection 5 Install Water Filtration System 6 Install Oven 8 Complete Installation 9 SÉCURITÉ DU FOUR ENCASTRÉ 11 EXIGENCES D INSTALLATION 12 Outillage et pièces 12 Ensemble encastré Four à micro ondes Four thermique Exigences d emplacement 12 Exigences d emplacement du système de filtration de l eau 13 Spécifications de l alimentation en eau 13 Spécifications électriques 14 INSTRUCTIONS D IN...

Page 2: ...ements IMPORTANT Observe all governing codes and ordinances Cabinet opening dimensions that are shown must be used Given dimensions provide minimum clearance with oven Recessed installation area must provide complete enclosure around the recessed portion of the oven Grounded electrical supply is required See Electrical Requirements section Electrical supply junction box should be located 3 7 6 cm ...

Page 3: ...he rear wall in the oven cabinet cutout Depending on your installation configuration more routing holes may be required Coil enough copper tubing inside the oven cabinet to allow for the connection to the oven to be made outside the oven cabinet prior to setting the oven in place Typical Installation Configuration NOTE For unique installations contact a licensed plumber A 28 71 9 cm recessed width...

Page 4: ...22 2 No O M91 latest edition and all local codes and ordinances A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 Electrical Connection To properly install your oven you must determine the type of electrical connection you will be using and follo...

Page 5: ...ufactured with a neutral white power supply wire and a cabinet connected green or bare ground wire twisted together 1 Disconnect power 2 Feed the flexible conduit from the oven through the opening in the cabinet 3 Remove junction box cover if it is present 4 Install a UL listed or CSA approved conduit connector to the junction box 5 Route the flexible conduit from the oven to the junction box thro...

Page 6: ...ater filter near the cold water supply pipe under the kitchen sink to filter the cold water IMPORTANT Be sure to allow a minimum clearance of 1 3 8 cm under the filter system for removing the filter cartridge Typical Installation Configuration NOTE For unique installations contact a licensed plumber 2 Attach the supplied water filter mounting ring and screw at the recommended location 3 Attach fil...

Page 7: ...he o ring until you hit the backstop 2 Connect another piece of copper water supply tubing to the quick connect adapter fitting you just installed on the filter outlet blue side of the water filter 3 Pull tube to ensure it is secured 4 Route copper tubing through undersink cabinet and oven cabinet cutout NOTE Due to temperatures around oven copper tubing is required 5 Connect the copper water supp...

Page 8: ... to the oven 6 Replace oven racks 7 Replace oven door s by inserting ends of hinges into hinge slots in the oven frame 8 Push hinges in as far as they will go and open the oven door You should feel the oven door drop into place 9 Rotate both hinge latches back to the locked position 10 Check that the door is free to open and close If it is not repeat the removal and installation procedures See Rem...

Page 9: ...icrowave safe container with 1 cup 250 mL of water and place container inside microwave oven Close door firmly 2 From the Main Menu touch MANUAL METHOD 3 Touch MANUAL COOK 4 Set microwave oven cook time to 2 00 minutes 5 Touch START If microwave does not operate check the following Household fuse is intact and tight or circuit breaker has not tripped Electrical supply is connected See Troubleshoot...

Page 10: ...10 Notes ...

Page 11: ... non respect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiels de ...

Page 12: ...e de cuivre relié au four Consulter les codes locaux en vigueur Vérifier les caractéristiques de la source d électricité existante Voir Spécifications électriques Il est recommandé de faire réaliser tous les raccordements des circuits électriques par un électricien qualifié agréé EnsembleencastréFouràmicro ondes Fourthermique Exigencesd emplacement IMPORTANT Observer les dispositions de tous les c...

Page 13: ...ération de vapeur doit être alimenté en eau froide sous pression de 30 à 120 lb po 207 à 827 kPa Au Massachusetts l installation doit être conforme aux critères du code de plomberie 248 CMR 3 00 10 00 Pour toute question au sujet de la pression de l eau contacter un plombier qualifié agréé Alimentation en eau par osmose inverse IMPORTANT La pression de l eau fournie à l entrée du four par un systè...

Page 14: ...nalétique de l appareil en bas à droite du châssis de l appareil derrière la porte Voir l illustration ci dessous Les modèles de 7 3 à 9 6 kW 240 volts 5 5 à 7 2 kW 208 volts doivent être alimentés par un circuit indépendant de capacité 50 A Les modèles de 7 2 kW ou moins de 240 volts 5 4 kW ou moins de 208 volts doivent être alimentés par un circuit indépendant de 30 A L emploi d un disjoncteur e...

Page 15: ...server la les porte s du four à part sur une surface de travail couverte Raccordementélectrique Le câblage d alimentation de ce four comporte un conducteur neutre blanc et un conducteur vert ou nu de liaison à la terre connecté à la caisse ces deux conducteurs sont torsadés 1 Déconnecter la source de courant électrique 2 Faire passer le conduit de câble flexible depuis le four à travers l ouvertur...

Page 16: ...t ou nu de liaison à la terre du câble du four avec un connecteur de fils homologation UL 3 Connecter ensemble les 2 conducteurs rouges G avec un connecteur de fils homologation UL 4 Installer le couvercle du boîtier de connexion Installationdufiltreàeau Installer le filtre à eau 1 Installer le filtre à eau à proximité de la canalisation d arrivée d eau froide sous l évier de la cuisine pour le fi...

Page 17: ...ient d être installé à l entrée du filtre jaune 3 Tirer sur le tube pour vérifier la qualité de chaque connexion S il est nécessaire de relâcher le tube Enfoncer la virole pour pouvoir libérer le tube alors que la virole est enfoncée tirer sur le tube pour l extraire Raccordement à la sortie du filtre à eau bleu 1 Installer le raccord fourni à droit ou coude pour connexion rapide sur le raccord de...

Page 18: ...n four double Insérer les vis à travers les trous des rails de montage Ne pas serrer excessivement les vis 5 Sur certains modèles l évent du four est immobilisé avec du ruban adhésif sur le côté du four Avec une vis n 8 14 x pour chaque côté de l évent fixer solidement l évent au four 6 Réinstaller les grilles du four 7 Réinstaller la les porte s du four insérer les extrémités des charnières dans ...

Page 19: ... émanation de chaleur S il n y a pas de vapeur d eau visible ou d émanation de chaleur ou si l afficheur présente un code d erreur F suivi d un chiffre plus E suivi d un chiffre commander l arrêt du four et contacter un technicien qualifié 7 Appuyer sur la touche OFF arrêt Contrôle du fonctionnement du four à micro ondes 1 Placer dans le four à micro ondes un récipient contenant 1 tasse 250 mL d e...