10.
Route direct wire through conduit and connect wires as
follows:
■
Form ground wire into a hook and wrap clockwise around
ground screw under washer. Tighten ground screw
securely.
■
Use twist-on connectors of proper size to connect direct
wire to 16-gauge wire dishwasher wiring. Connect black
wires together and white wires together.
11.
Reinstall terminal box.
IMPORTANT:
The tabs must be under the terminal box as
shown.
8
2.
Remove 5 screws (2 each side and above GFCI) holding the
metal front panel and remove panel.
3.
Remove terminal box screw and terminal box.
4.
Remove power cord green ground wire from under green
ground screw.
5.
Remove twist-on connectors and disconnect black and white
wires. Do not reuse connectors.
6.
Use pliers and squeeze locking
tab in the power cord strain
relief grommet.
7.
Remove power cord and grommet.
8.
Install a CSA-certified, U.L.- or C-U.L.-listed conduit
connector in power cord hole.
9.
Install conduit.
screws
screws
GFCI
front panel
green ground wire
do not remove this
grommet
power cord
conduit
connector
terminal box
screw
terminal
box
green ground screw
power cord
locking tab
WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector in
terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
green ground
screw
ground wire
direct wire
tabs
terminal box