5-3
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Refer to page 4-6 for the procedure for access-
ing the door interlock switches.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect the wires from the switch ter-
minals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
terminals of the
primary
or
secondary
interlock switch (normally-open). The
meter should indicate an open circuit (in-
finite).
5.
Touch the ohmmeter test leads to the
terminals of the
monitor
interlock switch
(normally-closed). The meter should indi-
cate a closed circuit (0
Ω
).
NOTE:
Pressing the actuator button should
result in opposite readings (normally-open
should read closed, and normally-closed should
read open).
DOOR INTERLOCK SWITCHES
Refer to page 4-8 for the procedure for access-
ing the lamp transformer.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect one of the wire connectors
from the LOAD and LINE transformer ter-
minals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
LOAD transformer terminals. The meter
should indicate less than 1
Ω
.
5.
Touch the ohmmeter test leads to the
LINE transformer terminals. The meter
should indicate approximately 45
Ω
.
LAMP TRANSFORMER
Summary of Contents for Architect Series KBMS1454R
Page 1: ...TECHNICAL EDUCATION JOB AID 4317377 KAC 45 Built In Microwave Oven Model KBMS1454R ...
Page 59: ...6 5 KEY TABLE FOR TEST MODE ...
Page 62: ...6 8 NOTES ...
Page 63: ...7 1 WIRING DIAGRAMS STRIP CIRCUITS SCHEMATIC DIAGRAM Electronic Control ...
Page 66: ...7 4 TIME OF DAY DISPLAYED CONDITION DOOR CLOSED ...
Page 68: ......