Display  Digital  Pressure  Sensor

G. 

INITIAL SETTING MODE

H. 

ADVANCE SETTING MODE

NOTE :

*1. When setting is “       ”, the power-save mode is active. 

      Please refer to the item “     ” in detailed.

*2. When setting “       ”or “       ”, the display copy function mode is active.  

      Please refer to the item “     ” in detailed.

I

P

KP50 

Series

 

Press        button for more than 3 seconds.

(*1)

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

Measure mode

OUT 1

Operating mode setting

OUT 1

type setting

OUT 2

Operating mode setting

OUT 2

type setting

Response time setting 

Display color setting

Unit setting

Measure mode

(oPS)

One point set

mode

Window comparator 

mode

Hysteresis 

mode

NC 

mode

NO mode

oFF mode 

(oPS)

One point set

mode

Window

comparator

mod

Hysteresis

mode

Use the         or         button to set OUT1 operating mode.

Use the         or         button to set OUT1 type.

Use the         or         button to set OUT2 operating mode.

Use the         or         button to set OUT2 type.

Use the         or         button to select response time.

ON:Green

OFF:Red

ON:Red

OFF:Green

ON/OFF:

Green

ON/OFF:

Red

Use the         or         button to set display color.

Use the         or         button to set desired pressure unit.

Alternately 

displayed

Alternately 

displayed

Alternately 

displayed

Alternately 

displayed

Alternately 

displayed

Alternately 

displayed

Alternately 

displayed

NC mode

NO mode

2.5ms

25ms

100ms

250ms

500ms

1000ms

1500ms

(*2) 

(*3)

(inHg)

(kPa/MPa)

(kgf/cm²) 

(bar)

(psi)

NOTE :

*1. This setting mode will not display when output 2 is set to oFF.

*2. Pressure unit is MPa with positive and high pressure. 

      Pressure unit is kPa with vacuum and compound pressure. 

*3. Only applicable for Vacuum/Compound.

(*1 )

(*2 )

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

Measure mode

Fixed hysteresis 

value selection

Display color selection

Power-Save 

Mode

Copy Function 

Setting

Restore factory 

setting

Measure mode

Press       button for more than 5 seconds.

Use the         or          button to adjust fixed hysteresis value.

Use  the          or          button to select LCD display color 

relation OUT1 or OUT2.

Use the         or         button to turn Power-Save mode on or off.

Use the        or         button to set copy function.

Use the         or        button to select to restore to default 

factory settings.

Alternately

displayed

*Applicable for one point set mode and window comparator mode.

*Hysteresis mode does not have this setting selection.

*       : When finishing copy, the slave sensor would be

           locked automatically.

*Only for KP50   -02-    and KP50   -04-    have this setting selection.

Alternately

displayed

Alternately

displayed

Alternately

displayed

Alternately

displayed