background image

PR-0325D

  

2017/12 Online Version

    

We reserve the right to change the specification without prior notice.

KITA SENSOR TECH. CO., LTD.

www.kita.com.tw

3 MPa

300 kPa

Rated pressure range
Setting pressure range
Withstand pressure
Fluid

Power supply voltage
Current consumption

Temperature characteristic

Port size

Lead wire
Weight

-0.100 ~ 2.00MPa

0.000 ~ 2.00MPa

10.0 ~ -101.3kPa

0.0 ~ -101.3kPa

-101.0 ~ 101.0kPa

-100.0 ~ 100.0kPa

-0.100 ~ 1.000MPa

0.000 ~ 1.000MPa

kPa

kgf/cm

2

bar
psi
inHg

Set pressure

resolution

0.1

MPa

0.001

0.01
0.01

0.1

0.1

0.001
0.001

0.01

Non-corrosive fluid SUS 316L

Sealed liquid

Silicon oil

12 to 24V DC ±10%, Ripple (P-P) 10% or less

±0.3% F.S. ±1 digit

IP65

±3% F.S. of detected pressure (25°C) at temp. Range of 0~50°C

Oil-resistance cable(0.15mm

2

)

A. 

SPECIFICATIONS

0 ~ 50°C

Approx. 110g (Rear ported) ; Approx. 145g (Bottom ported)

(Positive)

Repeatability (Switch output) 

Environment

F1:R1/4", M5 ; F2:NPT1/4", #10-32 UNF ; F3: G1/4"(BSPP), M5

F1C:Rc1/8"

KP50P-    -

(High)

KP50H-    -

(Vacuum)

KP50V-    -

(Compound)

KP50C-    -

Output type
Max. load current
Max. supply voltage
Residual voltage
Response time
Output short circuit protection

Yes

 40mA (With no load) 

1

2

3

4
5

6

7
8

Do not use corrosive fluid SUS316L, please confirm the specification in detailed.

Please use within the rating pressure range. Do not apply pressure beyond recommended maximum withstand pressure,  

permanent damage to the pressure sensor may occur. 

Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may be broken and 

can cause malfunction.

Turn power off before connecting wiring. Wrong wiring or short circuit will damage and/or cause malfunction. 

This product is not explosion-proof rated. Do not use in atmosphere containing flammable or explosive gases.

Wiring for 

pressure sensor should avoid power source line and high voltage line. If use in the same circuit, noise may cause 

malfunction.

The product is complied CE certificate, but no surge absorber. If required, please find other way to solve.

Do not exceed the screw-in torque of 13.6 N.m when installing piping. Exceeding this value may cause malfunction.

2 NPN or 2 PNP open collector 

125 mA

≤ 

1.5V

30V DC (at NPN output), 24V DC (at PNP output)

Switch

output

LCD display
Switch ON Indicator
Updates time
Indicator accuracy

Enclosure
Operation ambient temp. range
Storage ambient temp. range
Ambient humidity range
Withstand voltage
Insulation resistance
Vibration
Shock

Orange (1 & 2 Indicator) OUT1 OUT2

± 2% F.S. ± 1 digit (ambient temperature: 25 ± 3°C)

About 0.2s

Display

 2.5ms (chattering-proof function: 25ms, 100ms, 250ms, 500ms, 1000ms and 1500ms selections)

Voltage

output

Current

output

Voltage
Impedance
Current

Impedance

Linearity

±1% F.S.

4~20mA ( ± 2.5%)

Analog

output

35 ~ 85% RH (No condensation)

-10 ~ 60°C (No condensation or freezing)

250V AC in 1-min (between case and lead wire) 

50

 (at 500V DC, between case and lead wire) 

Total amplitude 1.5mm or 10G,10Hz-55Hz-10Hz scan for 1 minute, two hours each direction of X, Y and Z

100m/s

2

 

(10G), 3 times each in direction of X, Y and Z

KP50 

Series

 

0.001(~1.999)

0.01(2.00~)

0.01(~19.99)

0.1(20.0~)

0.01(~19.99)

0.1(20.0~)

0.1(~199.9)

1(200~)

For your safety, please read the following before using.

1~5V ( ± 2.5% F.S.)

Max.Load Impedance: 250

Ω

 at power supply of 12V

                                        600Ω

 at power supply of 24V

Mi

n.Load  Impedance: 50Ω

About 1kΩ

3½ digit, 7segment (red/ green)