MASTER CODE COMMANDS

SET THE TECHNICIAN CODE (PUBLIC USE FUNCTION ONLY) 
#

Master Code 

 10  

 Technician Code 

 Technician Code 

••

Example:

 

#

11223344 

 10 

 555555 

 555555 

••

Result:

 Technician Code 555555 now valid.

Note:

• The Technician Code will open lock without erasing the Public Use Code.

• Opening the lock with the Master Code or Sub-Master Code will erase the  

  Public Use Code.

DELETE THE TECHNICIAN CODE (PUBLIC USE FUNCTION ONLY)
#

Master Code 

11 

 11 

••

Example:

 11223344 

 11 

 11 

••

Result:

 Technician Code deleted.

SET DUAL CODE MODE (PRIVATE USE FUNCTION ONLY)
#

Master Code 

 12 

 12 

••

Example:

 

#

11223344 

 12 

 12 

••

Result:

 TWO valid codes required to open the lock or the Master Code only. 

They can be any combination of the following codes:

User Code + User Code

User Code + Sub-Master Code.

CANCEL DUAL CODE MODE (PRIVATE USE FUNCTION ONLY)
#

Master Code 

 13 

 13 

••

Example:

 

#

11223344 

 13 

 13 

••

Result:

 Lock will revert to only requiring one single code to open the lock.

Note:

 When switching between Program 12 and 13, codes and selected 

programs are retained.

 

Programming 
& Operating
Instructions

POI-KL1500-v3:0613

KL1

5O

O

MASTER CODE COMMANDS

RESTRICT THE LOCKED TIME (PUBLIC USE FUNCTION ONLY)
#

Master Code 

 14 

 (number of hours lock to remain locked) 

••

Example 1:

 

#

11223344 

 14 

 04 

••

Result:

• After 4 hours from the time it was locked, the Public Use Code will be  

  erased. A Master or Sub-Master Code now required to open the lock.

• Once opened with the Master or Sub-Master Code the lock will then revert to  

  B) Public Use with the lock open waiting for a new single Public Use Code

  to be entered.

• If the lock is opened during the set 4 hour period with a User or Master  

  Code then the lock will remain unlocked. At this point the restricted lock  

  time expires until a New User Code is entered.

Note:

• Program 16 (Auto-Open Time) will have priority if programmed. 

• The available restricted locked time periods in hours are:  

  00, 02, 04, 06, 08, 10 or 12.

• To end restricted locked time use following program:

#

Master Code 

 14 

 00 

••

Example:

 

#

11223344 

 14 

 00 

••

Result: 

Locked time will not be restricted i.e. will remain locked until User, 

Master or Sub-Master Code entered or Auto-Open Time, Program 16 is 

activated.

SET 24 HOUR CLOCK TO RUN (PUBLIC USE FUNCTION ONLY) 
#

Master Code 

 15 

 07 

 30 

••

Example:

 

#

11223344 

 15 

 07 

 30 

••

Result: 

Lock internal timer has been set to 07.30hrs and will start to run.

Note:

 Time must be reset for daylight saving when required.

MASTER CODE COMMANDS

SET AUTO OPEN TIME (PUBLIC USE FUNCTION ONLY)
#

Master Code 

 16 

 hour 

 min 

••

Example:

 

#

11223344 

 16 

 19 

 15 

••

Result:

 Lock will auto-open every day at 19.15 hrs and remain unlocked until a 

new code is entered.

Note:

 24 hr clock must be set before program will operate.

CANCEL AUTO OPEN TIME (PUBLIC USE FUNCTION ONLY)
#

Master Code 

 17 

 17 

••

Example:

 

#

11223344 

 17 

 17 

••

Result: 

Auto-Open Time is cancelled.

DISABLE/ENABLE SOUNDER 

The default is for the sounder to activate at every button press. To disable the 

sounder enter the following command:

#

Master Code 

 18 

 18 

••

Example:

 

#

11223344 

 18 

 18 

••

Result: 

 No sound when buttons pressed.

To enable the sounder, repeat above code sequence.

RED LED LOCKED STATUS (PUBLIC USE FUNCTION ONLY)

Note: 

The factory default is for the Red LED to flash when locked every 

3 seconds in B) Public Use.

#

Master Code 

 19 

 19 

••

Example:

 

#

11223344 

 19 

 19 

••

Result: 

When locked in B) Public Use – No Red LED flashing. 

To enable the Red LED to flash in B) Public Use, repeat above code sequence.

SUB-MASTER CODE COMMANDS

SET OR CHANGE THE USER CODE (PRIVATE USE FUNCTION ONLY)
#

Sub-Master Code 

 03 

 User Code ID 

 User Code 

••

Example:

 

#

55667788 

 03 

 03 

 1355 

••

Result:

 New User Code 1355 now valid in position 03.

SUSPEND INDIVIDUAL USER CODE (PRIVATE USE FUNCTION ONLY)
#

Sub-Master Code 

 04 

 User Code ID 

••

Example:

 

#

55667788 

 04 

 01 

••

Result:

 User Code ID number 01 valid but suspended. This will be identified by 

the Red and Blue LED signalling together after the code has been entered. 

Lock will remain locked.

RESTORE INDIVIDUAL USER CODE (PRIVATE USE FUNCTION ONLY)
#

Sub-Master Code 

 05 

 User Code ID 

••

Example:

 

#

55667788 

 05 

 01 

••

Result:

 User Code ID number 01 restored.

SUSPEND ALL USER CODES (PRIVATE USE FUNCTION ONLY)
#

Sub-Master Code 

 06 

••

Example:

 

#

55667788 

 06 

••

Result: 

All User Codes suspended. Red and Blue LED will signal together after 

every valid code is entered and lock will remain locked.

RESTORE ALL USER CODES (PRIVATE USE FUNCTION ONLY)
#

Sub-Master Code 

 07 

••

Example:

 

#

55667788 

 07 

••

Result: 

All User Codes restored.

SET OR CHANGE THE SUB-MASTER CODE 
#

Sub-Master Code 

 08 

 Sub-Master Code 

 Sub-Master Code 

••

  

Example:

 

#

55667788 

 08 

 22446688 

 22446688 

••

Result: 

Sub-Master Code 22446688 now valid.

SUB-MASTER CODE COMMANDS

USER CODES

TECHNICIAN CODES

DISABLE/ENABLE SOUNDER 

The default is for the sounder to activate at every button press. To disable the 

sounder enter the following command:

#

Sub-Master Code 

 18 

 18 

••

  

Example:

 

#

55667788 

 18 

 18 

••

 

Result: 

No sound when buttons pressed.

To enable the sounder, repeat above code sequence.

RED LED LOCKED STATUS (PUBLIC USE FUNCTION ONLY)

Note: The factory default is for the Red LED to flash when locked every 

3 seconds in B) Public Use. 

#

Sub-Master Code 

 19 

 19 

••

  

Example:

 

#

55667788 

 19 

 19 

••

 

Result: 

When locked in B) Public Use – No Red LED flashing.

To enable the Red LED to flash in B) Public Use, repeat above code sequence.

USER CODE COMMANDS

A User Code can change a User Code:

#

User Code 

 New User Code 

••

  

Example:

 

#

1234 

 0000 

••

 

Result:

 User Code has been changed from 1234 to 0000.

TECHNICIAN CODE COMMANDS

A Technician Code can open the lock when in B) Public Use WITHOUT 

deleting the User Code sequence: 

Enter 6 digit Technician Code 

 lock opens for 3 seconds and then relocks.