CODES - THE BASICS
OPERATING INSTRUCTIONS
PROGRAMMING CODES
• The KL1500 has four code levels
available:
i) Master Code
ii) Sub-Master Code
iii) User Code
iv) Technician Code
• The KL1500 is supplied with two
factory set codes:
Master Code: 11 22 33 44
User Code: 12 34
• Before fitting, change the Master
Code and User Code.
• All Master Codes and Sub-Master
Codes are 8 digits long.
• All User Codes are 4 digits long.
• Up to 20 individual User Codes
can be entered into the lock
at the same time. Each User Code
is entered together with specific ID
(Identification Number) from 01-20.
• All Technician Codes are
6 digits long.
• The lock ‘open’ time is set
at 4 seconds.
FUNCTIONS
Before programming, select the most
appropriate function for the application.
A) PRIVATE USE
Important Note:
This is the default function
pre-programmed in new locks.
This is the most common function
and is used where the
same code
will be repeatedly used.
B) PUBLIC USE
The user enters their own personal code
twice, the second time to confirm the
correct code. This locks the lock.
To open the same code is entered once
again and then will be erased.
The lock will remain open until a new
code is entered.
This function is used for short term,
multi occupancy applications eg:
a locker in a leisure centre or Spa.
The KL1500 has a 12 button keypad.
The # button is used as a prefix when
programming for all code levels.
The KL1500 standard unit is installed in the
vertical (up) position with the lever at the
bottom. However, the lock may be installed
in any of 4 positions; up, down, horizontal
(left or right). Should the lock need to be
changed from one position to another
please see Installation Instructions.
SUB-MASTER CODE
The Sub-Master Code can:
• Open the lock.
• Change the Sub-Master Code.
• Set, change, suspend or restore
User Codes.
• Set lock status indicator.
• Disable or enable sounder.
USER CODE
The User Code can:
• Open the lock.
• Change the User Code.
TECHNICIAN CODE
The Technician Code can:
• Open the lock in Public Use
Function without erasing the
User Code.
The same code can be used in one
level only.
Blue LED = Code accepted
Red LED = Code rejected
BATTERY OVERRIDE
Should the batteries fail the lock can be
opened using the code and an external
PP3 battery as the power source as
follows:
The procedure is as follows:
• Place the +positive contact
of the battery against the contact
point surrounding the Red LED and
the –negative contact point of the
battery against the contact point of the
Blue LED.
• Enter Master Code.
• Lock will open.
• Remove the lock and replace batteries.
• Refit lock.
PROGRAMMING INSTRUCTIONS
CHANGE THE MASTER CODE
#
Master Code
•
01
•
New Master Code
•
New Master Code
••
Example:
#
11223344
•
01
•
22334455
•
22334455
••
Result
: Master Code has been changed to 22334455.
SELECT PRIVATE USE OR PUBLIC USE FUNCTION
#
Master Code
•
02
•
####
•
****
••
Example
:
#
11223344
•
02
•
####
•
****
••
Result
: If lock was set in A) Private Use it will now work in B) Public Use.
If lock was in B) Public Use it will now work in A) Private Use.
Note:
• Factory default is A) Private Use.
• In B) Public Use the Red LED is factory set to flash every 3 seconds when
locked, unless overridden by Program 19.
SET OR CHANGE THE USER CODE (PRIVATE USE FUNCTION ONLY)
#
Master Code
•
03
•
User Code ID
•
User Code
••
Example
:
#
11223344
•
03
•
02
•
1455
••
Result
: New User Code 1455 now valid in position 02.
SUSPEND INDIVIDUAL USER CODE (PRIVATE USE FUNCTION ONLY)
#
Master Code
•
04
•
User Code ID
••
Example
:
#
11223344
•
04
•
01
••
Result
: User Code ID number 01 valid but suspended. This will be identified
by the Red and Blue LED signalling together after the code has been entered.
Lock will remain locked.
MASTER CODE COMMANDS
RESTORE INDIVIDUAL USER CODE (PRIVATE USE FUNCTION ONLY)
#
Master Code
•
05
•
User Code ID
••
Example
:
#
11223344
•
05
•
01
•
Result
: User Code ID number 01 restored.
SUSPEND ALL USER CODES (PRIVATE USE FUNCTION ONLY)
#
Master Code
•
06
••
Example
:
#
11223344
•
06
••
Result
: All User Codes suspended. Red and Blue LED will signal together after
every valid code is entered and lock will remain locked.
RESTORE ALL USER CODES (PRIVATE USE FUNCTION ONLY)
#
Master Code
•
07
••
Example
:
#
11223344
•
07
••
Result
: All User Codes restored.
SET OR CHANGE THE SUB-MASTER CODE
#
Master Code
•
08
•
Sub-Master Code
•
Sub-Master Code
••
Example
:
#
11223344
•
08
•
55667788
•
55667788
••
Result
: Sub-Master Code 55667788 now valid.
DELETE THE SUB-MASTER CODE
#
Master Code
•
09
•
09
••
Example
:
#
11223344
•
09
•
09
••
Result
:
The Sub-Master Code is deleted.
MASTER CODE COMMANDS
•
Code accepted
•
Code rejected
low battery indication
The programming functions
of the code levels are:
LOST MASTER CODE PROCEDURE
• Remove BOTH coin cell batteries.
• Press and hold the 0 button.
• Replace one battery, Blue LED will
flash twice.
• Release the 0 button and within three
seconds press the 0 button 3 times.
• Blue LED will flash twice and the
lock will revert back to last active
mode – Public Use or Private Use
Function and the Master Code
will now be the factory default e.g.
11223344.
Note:
All previously programmed
codes and settings will be
RETAINED.
• Replace second battery.
FACTORY CODE RESET
Reset lock to factory supplied settings:
• Remove both batteries.
• Press and hold the 1 button and replace
one battery.
• The blue LED will flash twice and
beep twice.
• Release the 1 button and within 3 seconds
press the
*
button 3 times.
• The blue LED will flash and beep twice to
confirm factory reset.
• Refit second battery.
Note:
Lock will revert to Master Code of
11223344 and User Code 1234.
All previously entered settings and codes
will have been
ERASED
.
MASTER CODE
The Master Code can:
• Open the lock.
• Change the Master Code.
• Set Public Use or Private Use Function.
• Set, change or delete the Sub-Master Code.
• Set, change, suspend or restore User Codes.
• Set or delete Technician Code.
• Set or cancel Dual Code mode.
• Set or cancel hours locked time.
• Set 24hr clock.
• Set or cancel Auto-Open Time.
• Set lock status indicator.
• Disable or enable sounder.
PENALTY TIME
• Entering three incorrect codes will
cause the lock to shut down for 10
seconds.
BATTERY POWER
• The KL1500 should provide in excess
of 50,000 openings of 4 seconds
each from 2 x CR2450 3.0 V coin cell
batteries.
LOW BATTERY
• When battery power is low the Red
LED will flash 3 times before the Blue
LED light accepting the code. Fit new
batteries as soon as this happens.
Note:
To retain Program 15 Time
Setting, one battery must be changed
at a time.