Kisae SC 1210 Owner'S Manual Download Page 4

Step 2: Connecting a 12V battery 

 

Connect  ‘-‘  terminal  of  Energy  Storage  (pin  4)  on  unit  to  12V  battery 
negative terminal 

 

Connect  ‘+’  terminal  of  Energy  Storage  (pin  3)  on  unit  to  12  V  battery 
positive terminal 

Step 3: Connecting a PV panel 

 

Connect  ‘-‘ terminal  of  Solar  Input  (pin  2)  on  unit to  PV  panel  negative 
terminal 

 

Connect  ‘+’  terminal  of  Solar  Input  (pin  1)  on  unit  to  PV  panel  positive 
terminal 

Step 4: Connecting a DC load 

 

Connect ‘-‘ terminal of Load Output (pin 6) on unit to PV panel negative 
terminal 

 

Co

nnect ‘+’ terminal of Load Output (pin 5) on unit to PV panel positive 

terminal 

Note: Maximum wire size of AWG#10 can be used on the terminal and tighten 
the screws snugly. 

 

6.  Operation and Maintenance 

The unit is fully automatic and no unit setting is required once it is installed 
properly. It is recommended to verify the state of charge of the battery regularly 
and to verify that the load connected to the unit is not over rated for the unit. It 
is also recommended to verify that the power consumption on the load is less 
that the PV panel can produce.   
The following periodic inspections and maintenance tasks are highly 
recommended for best performance. 

 

Check for any rusting or corrosion around the battery terminals 

 

Verify the PV panels and loads connected do not exceed the unit rating 

 

Tighten  all  the  7  terminal  screws  and  inspect  for  any  loose,  broken  or 
burnt wire connections.   

 

Ensure PV panel is mounted properly and is placed in the right position. 
Check for any dirt, debris and corrosion on the panel. 

 

Periodically clean solar panels with water and do not use chemicals 

 

7.  Troubleshooting 

No Output: 

 

Check  DC  load  terminal  connection.  Connection  may  be  loose  or 
disconnected.   

 

Check connection polarity. Reverse polarity on any terminals will damage 
unit and is not covered by warranty. 

 

Verify battery voltage is not too low. 

 

For LD model, check Load disconnect LED is ON. Verify battery voltage 
is above 12.6V. 

Battery did not charge: 

 

Verify the PV panel is functioning properly. Check for poor connection on 
the PV panel 

 

Verify PV panel is not blocked by any surrounding tall objects. Check the 
PV panel surrounding area. 

 

Check  PV  and  battery  connection.  Loose  connection  will  reduce  unit 
performance. 