9.5 Use of Quick Disconnect
A quick disconnect can be used with all bail out systems.
It provides greater convenience on deck while dressing the
diver. It also makes it possible to separate the attachment
of the bail-out from the helmet should the diver become
entangled underwater.
The quick connect is designed to be installed in any low
pressure port of the diver’s bail-out regulator. The connec-
tor splits the hose into two halves, with a male connector on
one end and a female connector on the other. The female
connector should be equipped with a sleeve lock that must
be properly aligned before the hose can be disengaged.
Double shut off quick connects are recommended over
open quick connects.
One end of the connector is designed to be attached to the
EGS valve assembly, while the other end of the connector
is designed to attach to any of the standard low pressure
ports on the SuperFlow
®
first stage regulator (or any high
performance regulator) used for the bail-out supply.
A quick disconnect makes setting up your helmet and
bail-out system much easier.