![Kirby Morgan KMB-18 A/B Operation And Maintenance Manual Download Page 29](http://html1.mh-extra.com/html/kirby-morgan/kmb-18-a-b/kmb-18-a-b_operation-and-maintenance-manual_1971899029.webp)
KMB 18 & 28 MANUAL
page 19
Document # 010518001 © Copyright 1970-2003 Kirby Morgan Dive Systems, Inc. All rights reserved.
DANGER: If the bands become
loose the hood and face seal could sepa-
rate from the mask. This would cause the
mask to flood which could cause drown-
ing.
2.2.2 Clean Face Port (27)
Remove any sand or dirt on the interior of the face
port (27) which might cause scratches when anti-
fogging solution is applied prior to the next dive.
10) Be sure to inspect the bands themselves (16 &
68). The welds must show no signs of cracking or
parting.
2.2.4 One-Way Valve (104) Check
There are two ways to check the one-way valve
(104). Check both ways if possible.
1) Leaving the auxiliary knob (100) open (on) and
not hooked up to the supply hose, try to suck air
out of the adapter (105). If any air comes out, the
one-way valve must be replaced.
2.2.3 Check Moving Parts
Check all moving parts, such as the regulator
adjustment knob (47), the defogger control knob
(85), auxiliary knob (100), and the nose block
device knob (34) to ensure smooth and proper
operation.
WARNING: The one way valve must
be tested dailly, prior to commencement
of diving operations. Failure of the one
way valve could cause serious injury or
death.
Fig. 2.1 Clean the face port prior to use.
Fig.2.2 Moving parts, such as the regulator adjustment
knob must be checked before the Band Mask is put on
line.