5.
OPERATE THE GENERATOR SET
5.1Operate the generaor set
1. Warm up the engine without load three minutes.
2. Concerning the generator set with Low Oil Alarm System, check that the Low
oil alarm Lamp is not lit.
CAUTION
For the generator set with Low Oil Alarm System, the Oil Alarm Lamp will
activated by low oil pressure or engine oil shortage, simultaneously, the
engine will stop. The engine will stop immediately if restarted without
refilling the engine oil. Check the oil level and refill.
Do not loosen or readjust either the engine speed limiting bolt or fuel
injection limiting bolt, the performance will be affected.
5.2 Checks during the running
1. Whether there is abnormal sound or vibration;
2. Whether the engine misfires or runs rough;
3. Check the color of the exhaust. (Is it black or too white?)
If you notice any of the above-mentioned phenomenon happened, stop the en-
gine and find out the fault cause or contact with KIPOR agent.
If the engine has been running, the muffler will be very hot. Be careful not to
touch the muffler.
Never refill the fuel tank while the engine is running.
CAUTION
Fluorescent
lamp
Motor
driven
equipment
X1
X2
X3~5
X1
X1.5
X2
100VA
(W)
100VA
(W)
80VA
(W)
60VA
(W)
450-750VA
(W)
300VA
40W
100W
switch power
Rectify power
X2
X2
Computer UPS
power 200W
400VA
400VA
6.3 Electrical appliance particularly motor-driven equipment will produce very
high current while starting, the below table provides the reference for connecting
these apparatus to the generator set.
APPLIANCE STARTIN GRATED
Refrigerator
150W
TYPICAL
APPLIANCE
TYPE
WATTAGE
EXAMPLE
STARTIN GRATED
Incande-
scent lamp
Heating
appliance
Incande-
scent
lamp
TV
Incande-
scent
lamp
Fluorescent
lamp
Fluorescent
lamp
Refrigerator
Electric fan
Motor Electric
drill Computer
UPS power