background image

D I G I TA L
G E N E R A T O R

I G 3 0 0 0 E

WUXI KIPOR POWER CO., LTD.

Summary of Contents for IG3000E

Page 1: ...D I G I TA L G E N E R AT O R IG3000E WUXI KIPOR POWER CO LTD...

Page 2: ...Pay special attention to statements preceded by the following words Failure to properly follow these precautions can result in property damage serious injury or DEATH Read all labels and the owner s m...

Page 3: ...CATION 3 PRE OPERATION CHECK 4 STARTING THE ENGINE 5 GENERATOR USE 6 STOPPING THE ENGINE 7 MAINTENANCE 8 TRANSPORTING STORAGE 9 TROUBLESHOOTING 10 SPEIFICATIONS 11 ELECTRICAL WIRING DIAGRAM 12 WARRANT...

Page 4: ...uld result in personal injury or equipment damage Exhaust gas contains poisonous carbon monoxide Never run the generator in an enclosed area Be sure to provide adequate ventilation The muffler becomes...

Page 5: ...ake a pre operation inspection page 9 before you start the engine You may prevent an accident or equipment damage Place the generator at least three feet or one meter away from buildings or other equi...

Page 6: ...ve the oil filler cap and wipe the dipstick with a clean rag Check the oil level by inserting the dipstick in the filler hole without screwing it in See Fig 3 The engine may be damaged while running i...

Page 7: ...ng methanol that does not also contain co solvents and corrosion inhibitors for methanol Never use gasoline containing more than 5 methanol even if with co solvents and corrosion inhibitors Fuel syste...

Page 8: ...position to start the engine Refer to 6 Fig Fig Pull out the chock valve handle to close the chock valve Fig 5 Turn the fuel valve handle to the ON position pull out the chock valve handle to close t...

Page 9: ...d DC Most appliance motors require more than their rated wattage for start up WARNING CAUTION AC applications 1 Start the engine and make sure the output indicator light green comes on 2 Confirm that...

Page 10: ...lights the overload indicator light red may damage the generator Marginal overloading that temporarily lights the overload indicator light red may shorten the service life of the generator Be sure th...

Page 11: ...ry 2 years Replace if necessary 2 Maintenance Schedule CAUTION WARNING 3 The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition Inspect or serv...

Page 12: ...the element 3 Reinstall the air cleaner cover NOTE WARNING CAUTION 3 FUEL SEDIMENT CUP SERVICE Gasoline is extremely flammable and explosive under certain conditions Do not smoke or allow flames or sp...

Page 13: ...nance cover 3 Once a month recharge the battery 4 Change the engine oil 5 Remove the spark plug and pour a tablespoon of clean engine oil into the cylinder Crank the engine several revolutions to dist...

Page 14: ...und 4 Pull the recoil starter sparks should jump across the gap To check 1 Turn off the fuel valve and remove the drain screw 2 Turn on the fuel valve Fuel should flow the fuel tank Be sure there is n...

Page 15: ...430 mm 77 lbs 35 kg 11 ELECTRICAL WIRING DIAGRAM DC Receptacle Charging winding Blue Blue Blue Blue Rectify Bridge Red Black Red Black Green Green Black White Brown Gray Yellow Green Inverter Yellow...

Page 16: ...the property of Coast Distribution TO OBTAIN WARRANTYSERVICE Contact any authorized dealer or contact our national customer service center at Phone 1 877 544 4449 Fax 1 800 263 0280 E mail kiporcare...

Reviews: