6. STOPPING THE ENGINE
To stop the engine in an emergency, turn the engine switch to the OFF position.
IN NORMAL USE:
1. Turn the engine switch to the OFF position.
2. Switch off the connected equipment and pull the inserted plug.
3.Turn the fuel valve lever to the OFF position.
Be sure both the fuel cap vent lever and the engine
switch are in "OFF" position when stopping,
transporting and/or storing the generator.
CAUTION
7. MAINTENANCE
NOTE: (1) Log hours of operation to determine proper maintenance.
(2) Service more frequently when used in dusty areas.
(3) These items should be serviced by an authorized dealer, unless the owner has the proper tools
and is mechanically proficient. See the Shop Manual.
ITEM
Perform at every indicated month
or operating hour interval, which-
ever comes first.
REGULAR SERVICE PERIOD(1)
Fuel line
Check
Check level
Change
Check
Clean
Clean-adjust
Clean
Check-adjust
Clean
Engine oil
Air cleaner
Spark plug
Sediment cup
Valve clearance
Fuel tank and filter
EVERY
YEAR
OR
200 HRS
EACH
USE
FIRST
MONTH
OR
20HRS
EVERY 3
MONTHS
OR
50HRS
EVERY 6
MONTHS
OR
100 HRS
(2)
(3)
Every 2 years (Replace if necessary) (2)
Maintenance Schedule
CAUTION
WARNING
(3)
The purpose of the maintenance and adjustment schedule is to keep the generator in
the best operating condition.
Inspect or service as scheduled in the table below.
Shut off the engine before performing any maintenance. If
the engine must be run, make sure the area is well
ventilated. The exhaust contains poisonous carbon
monoxide gas.
Use genuine our parts or their equivalent. The use of
replacement parts which are not of equivalent quality
may damage the generator.
2. Start the engine
The DC receptacle may be used while the AC power is
in use.
An overloaded DC circuit will trip the DC circuit
protector. If this happens, wait a few minutes before
pushing in the circuit protector to resume operation.
Low oil alarm system
The low oil alarm system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the crankcase falls
below a safe limit, the low oil alarm system will automatically shut down the engine(the
engine switch will remain in the ON position).
If the low oil alarm system shuts down the engine, the low oil alarm indicator light(red)
will come on when you operate the starter, and the engine will not run. If this occurs,
add engine oil.
NOTE