![Kipor IG3000 Operation Manual Download Page 15](http://html1.mh-extra.com/html/kipor/ig3000/ig3000_operation-manual_1971722015.webp)
Inspect the spark arrester screen for holes or tears. Replace if necessary.
NOTE
4.Reinstall the spark arrester.
5.Reinstall the upper back cover.
-21-
Spark arrester
Back cover
Fig. 16
7.6 Spark arrester maintenance
WARNING
CAUTION
If the generator has been running, the muffler will be very hot. Allow it to
cool before proceeding.
-20-
1.Remove the bac
k cover.
2.Remove the exhaust tail pipe and spark arrester.
3. Use a brush to remove carbon deposits from the spark arrester screen.
The spark arrester must be serviced every 100 hours to maintain its efficiency.
Drain
plug
Fig. 17
8.TRANSPORTING/STORAGE
8.1 When transporting the generator, turn the fuel valve lever OFF and keep
the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite.
o
6.Slowly pull the starter grip until resistance is felt. At this point, the piston is
coming up on its compression stroke and both the intake and exhaust valves
are closed.
Storing the engine in this position will help to protect it from internal corrosion.
8.2 Before storing the unit for an extended period:
1.Be sure the storage area is free of excessive
humidity and dust.
2. Drain the fuel
a. Open the left side maintenance cover.
b. Turn fuel valve lever to ON and then loosen the
carburetor drain screw. Drain the gasoline fr m the
carburetor and fuel tank into a suitable container.
c.Tighten the carburetor screw, close the fuel valve lever and left side
maintenance cover.
3. Once a month, recharge the battery.
4.Change the engine oil.
5. Remove the spark plug and pour about a tablespoon of clean engine oil into the
cylinder. Crank the engine several revolutions to distribute the oil, then reinstall the
spark plug.