FP 25 E
Operating Elements
Issue: 06/2011
51
4 .5 .3 Ammeter
The ammeter shows the set intensity of currents.
»
The small lamphouse (1000 to 2000 W) is equipped with a 100 A ammeter.
»
The big lamphouse (2000 to 7000 W) is equipped with a 200 A ammeter.
4 .5 .4 Ignition Button
The xenon lamp automatically ignites when pushing the start button on the projector
operating panel.
You can manually ignite the xenon lamp by pushing the ignition button.
ATTENTION
Do not push this button for more than 0.5 seconds. The xenon bulb can be damaged
if you push for a longer time. If the xenon lamp does not ignite after you have pushed
the button two to three times, the ignition unit or the rectifier or the xenon bulb probably
have a defect.
4 .5 .5 Fuse
If you put out the fuse the lamphouse is separated from mains.
ATTENTION
You have to screw out the fuse at all maintenance work and cleaning.