To insert the cable, align the key
ways on the extension cable with the
circular receptacle on the ballast.
Rotate the locking ring until it clicks
into the lock position. Lamps can
operate as far as 75 feet from the
ballast. (3 x 25ft extensions)
A Splitter can be used at the Ballast
or on the end of an Extension Cable
to split a 4Bank run into either
4 Singles or 2 Doubles.
This allows for greater rigging
flexibility.
WARNING!
1) ALWAYS TURN OFF THE BALLAST BEFORE connecting or
disconnecting Lamps, Harnesses or Extension Cables.
2) Use only with Sine wave inverters. Do not operate on SCR dimmers.
3) If powering the ballasts through a Dimmer Pack set the Dimmer to
Non-Dim Mode.
The 120 VAC Ballast requires 110 to 130 Volts AC 50/60 Hertz on an earth
grounded circuit; the 230 VAC Ballast requires 220 to 240 Volts AC on an
earth grounded circuit. The electronic Ballast operates at a high frequency of
25KHz. It is dead–quiet, instant–on and lightweight.
Load Considerations:
Kino Flo ballasts are not power factor corrected. They will draw double the
current on the neutral from what is being drawn on the two hot legs. On large
installations it may be necessary to double your neutral run so as not to