15
that the SIM card has data service available in advance and write down the SIM card
number.
4.1.2 Main unit power on
After installing the SIM card, turn the battery switch to the ON position. When the
red light starts to blink, indicating that the device is powered on.
4.1.3 Major parameter setting by SMS or SSCOM tool
SMS list:
APN,apn,user,pwd#
Set APN, User name and password
For example:
APN,CMNET,internet,internet#
APN:CMNET
Username: internet
Password: internet
APN,CMNET#
APN:CMNET
User name: Null
Password:Null
IP and port
Set IP, port and communication type of primary server ,
For example:
IP,119.23.233.52,6000,1#
Set the primary server IP:119.23.233.52
,
port 6000
,
communication type:TCP
IP,www.365qczx.com,6000,0#
Set the primary server domain:www.365qczx.com
,
Port
6000
,
communication type UDP
UTC,TTTT#
Set time zone, unit minute ,default UTC+8:00
STATUS#
Query communication status of the device
FACTORY#
Device resume to factory setting
RESET#
Restart the device
CENTER,A,#
Set center number
SSCOM configuration:
Com tool download link and follow up the guide for configuration:
http://dl.vodofo.com/KingwoTool20220218.rar
Mounting recommendations