7
Set storage mode
STORAGE,T#
For example:
STORAGE,2880#
indicates enter into storage
mode, upload data each 2880
minutes
T
:
Upload
interval
Unit:
Minutes
Value
range:
2880-43200
minutes
(
2-30
days
)
Exit storage mode
STORAGE,0#
Note:
This mode is designed for power save purpose before the devices goes to field:
1.Under warehouse mode, if light sensor triggered, device will exit warehouse
mode
2.Under warehouse mode, if other work mode has been configured, device will exit
warehouse mode
3.Under warehouse mode, device can’t be wake up by vibration
4.Under warehouse mode, use command STORAGE,0# to exit warehouse mode
2.1.3 Regular upload mode (Recommended)
Configuration
SMS Command
Set regular upload mode
HX,T# or MODE,0,T#
For example
HX,1440# or MODE,0,1440# indicates
upload each 1400 minutes (24 hours)
T
:
Upload
interval
Unit: Minutes
Value range:
5-43200min
utes
(
2-30
days
)
Exit storage mode
STORAGE,0#
Note:
Default setting is wake up each 1440 minutes(24 hours)
Fixed upload mode can’t be wake up by motion
2.1.4 Clock mode
Configuration