background image

LED Tunnel light Installation instruction

 Product Dimension

Product outline drawing of    type bracket

Product outline drawing L Type bracket

Product Dimension

Unit

Warning: 1. In any case the luminaire shall not be installed on the surface of combustible material.
2. LED module is not replaceable.

4. The broken cable or wire in this luminaire shall only be replaced by a KINGSUN employee or agent or
    a similar qualified person.
5. In order to prevent accidents that threaten personal safety, please install and use them in strict
    accordance with the instructions.
6. Cut off the power supply before installation to prevent electric shock and need professional electrician
    to operate.
7. Ground wire of power supply and controller for all luminaires with 220V input shall be grounded.

Installation instruction

L type bracket installation schematic diagram

the distance between two holes is as below drawing. Thwack

M10mm expansion screws into the holes as shown in the drawing.
Remark: Recommended punch depth >60mm.

Step two: Fix the luminaire onto M10 screws and lock the

L type installation board onto the concrete wall with flat

washer, spring washer and M10 nuts.

Note that the arrow points to the driving direction during installation.

Step three: Connect the power supply cable with remaining power
cable and do insulation and waterproof treatment.
Connection detail A (Please choose the actual power supply cable
color when do connection.)

Detail A

Detail A

Green/Yellow green

Please connect the same

color or same polarity.

Remaining cable

Step one

 

the distance between two holes is 160mm. Thwack M10mm
expansion screws into the holes as shown in the drawing.

Remark: Recommended punch depth >60mm.

Step Two: Lock the installation board onto the concrete wall

with flat washer, spring washer and M10 nuts. The M10 nut

must be locked with a torque greater than 10.5 N.M.
Note that the arrow points to the driving direction during
installation.