10. INSTALLATION

NOTE: INSTALLATION AND REPAIR
SHOULD BE PERFORMED BY A
QUALIFIED SERVICE PERSON. THE
APPLIANCE SHOULD BE INSPECTED
BEFORE USE AND AT LEAST ANNUALLY
BY A PROFESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING MA Y BE
REQUIRED DUE TO EXCESSIVE LINT
FROM CARPETING, ETC. IT IS
IMPERATIVE THAT THE CONTROL
COMPARTMENT, BURNING AND
CIRCULATING AIR PASSAGEWAYS OF
THE APPLIANCE BE KEPT CLEAN. 

Install the fireplace insert in the following order: 

1. Make sure that the insert will fit into the fire

place. Most Zero Clearance wood fireplaces
will need to be modified. The refractory can be
removed if necessary and the front of the
appliance can be altered to allow the insert to
fit into the cavity. Holes will have to be made
in the firebox for the entry of gas and electrical
but the chamber must not be altered beyond
this. 

2. Clean and inspect chimney. 
3. Plan layout of gas line. 
4. Plan layout of electrical. 
5. Install the chimney liner as instructed in

SECTION 9. 

6. Clean out and vacuum the solid fuel fireplace.

Make sure that the fireplace is completely
cool and has not been used for a few days. 

7. Make sure that the solid fuel fireplace base is

level and if not make any necessary
adjustments. 

8. Slide unit into place attaching draft hood and or

chimney liner as required. 

9. Hook up gas line. 

10. Hook up electrical. 
11. Remove glass by removing two screws behind

upper grill and lifting door off bottom door
retainer (glass is very fragile). 

12.

Log Installation: 

- Remove logs from carton (4) and inspect. 
- Install as per Log Placement set up. 
- Purge lines and test pilot operation. 

13. 

Ember Kit Instructions: 

Spread supplied rock evenly on the bottom

of the fireplace around the log set (DO NOT
PLACE ROCK ON BURNERS), next tear
ember wool into small thin pieces and place
evenly over front burner . 

14. Re-install the glass door. 
15. Check for correct operation 

(See SECTION 12) 

16. Install Surround and Grills as per

instructions. 

17. Gas fired appliances may be used only for

supplemental heat and/or decorative
purposes and under no circumstances shall
they provide a primary heat source.. 

NOTE:  DO NOT BLOCK THE SIDES OR 

TOP OF THE APPLIANCE AS THIS WILL

AFFECT THE PROPER AND SAFE 

OPERATION OF THE UNIT. 

Summary of Contents for VFI25LP

Page 1: ...anual Installation and service must be performed by a qualified installer service agency or the gas supplier Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this...

Page 2: ...wn between each Be aware during log and firebox paint curing that a white deposit may be developing on the inside of the glass doors It is important to remove this white deposit from the glass doors w...

Page 3: ...0 11 Field Conversion for C30GEK 11 12 Combustion Air Unit Operation Checkout 12 14 Unit Adjustment 13 15 Maintenance 14 16 Surround and Brass Trim Assembly Instructions and Parts List 15 17 Surround...

Page 4: ...variable gas input 3 HEAT OUTPUT It must be remembered that both the units in this manual produce significant amounts of heat within a varying input range VFI25N NATURAL GAS 0 4500ft Output BTU HR In...

Page 5: ...the front of the unit to a combustible floor is 0 15 metres 6 inches Clearance from adjacent side wall is 7 inches from side of unit Minimum clearances from the top of the grill to a mantel and maxim...

Page 6: ...imney or other approved venting system the chimney must be inspected cleaned and rep aired if necessary A chimney which was used for a solid fuel fireplace must be professionally cleaned in order to r...

Page 7: ...in place 19 is required 6 If the lintel is wider than 12 305mm then the height of the solid fuel fireplace must be at least 25 63 5 cm to allow for an offset elbow See Figure 2 If providing an offset...

Page 8: ...solid fuel fireplace Make sure that the fireplace is completely cool and has not been used for a few days 7 Make sure that the solid fuel fireplace base is level and if not make any necessary adjustm...

Page 9: ...and pull forward to the grate bars Place log 2 on rear log holder and center it Step 3 Place Log 3 onto the notched areas as shown Place Log 4 onto the notched areas as shown Refer to step 2 for notch...

Page 10: ...to step 2 for Log 5 notch locations Fill the exposed areas of the ember plates and front burner tube with ember rocks Do not place ember rocks on rear burner tube Step 4 Place lava rock around the sid...

Page 11: ...rill 1 8 Drill Bit 1 4 Nut Driver Bit Step 1 Remove existing grate bar by bending bar slightly forward and drill out rivets Step 2 Seal rivet holes with two supplied screws ZDV6000 ONLY Step 3 Center...

Page 12: ...not be allowed to contact glass and unit should be allowed to run for a minimum of 10 minutes area of sensing tube will become quite hot A minimum draft pressure of 02 inches of water column is requi...

Page 13: ...left of the valve E Inlet Pressure and A Manifold Pressure and connecting a manometer Pressure ranges are as listed below Gas Supply Pressure inches w c Min Normal Max Natural Gas 4 5 7 0 9 0 L P pro...

Page 14: ...ple is necessary replace from top and bottom of firebox bottom Reference lower diagram Page 18 c Logs CAUTION The logs can stay hot for several hours after the fireplace is shut off Serious burns coul...

Page 15: ...placement For valve replacement it is recommended that the burner assembly be removed this is done by removing two 1 4 hex screws on the left and right side of the firebox and lifting the complete bur...

Page 16: ...ure all panels All brass trims D E and F are installed with 5 16 x 6 32 self tapping screws attach part D E and F to outer edge of surround Than place On Off switch into slot upper right corner after...

Page 17: ...Brass Trim Top 1 E 3000 305 3000 315 3000 330 Brass Trim Left 1 F 3000 306 3000 316 3000 329 Brass Trim Right 1 G 3000 307 3000 317 3000 324 Brass Panel Top 1 Gl n a n a 3000 327 Brass Panel Bottom 1...

Page 18: ...ITCH Wiring Diagram SIT 820 639 and 820 640 True Millivolt Systems This System does not have a thermocouple For units with serial number greater than 13930 see 820639 820640 systems Wiring diagram wit...

Page 19: ...Kit Antique Brass V25T2129C Trim Kit Chrome V25T2129P Trim Kit Polish Brass Size 21 High x 29 Wide V25S2738B Surround Kit Large Flat Black V25T2738A Trim Kit Antique Brass V25T2738C Trim Kit Chrome V...

Page 20: ...ts are not available for Deluxe Surrounds V25ADDX Arch Door Frame Deluxe Black 352 V25ADTH Arch Door Frame Top Half Black 353T V25ADDA Arch Door Frame Double Arch Black 354 V25ADDD Arch Door Frame Dou...

Page 21: ...P136WR Thermopile GOAI 524 1001 P069SI Electrode Sparker 915 069 TC SIT 1001 P216SI Thermocouple 290 216 TC SIT 1001 P165SI Orifice Pilot NG 977 165 TC SIT 1001 P167SI Orifice Pilot LP 977 167 TC SIT...

Page 22: ...Hood Assembly 2000 079 Gasket for Flue 2500 BNGSI Burner Assy c w Valve Natural Gas 2500 BLPSI Burner Assy c w Valve Liquid Propane 3000 930 Spill Safety Switch 36T21 3000 940 Glass Robax 23 22 x 11 7...

Page 23: ...ot screw to provide proper sized flame Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire Size Max Length 14 GA 100 FT 16 GA 64 FT 18 GA 40 FT 20 GA 25 FT 22 GA 16 F...

Page 24: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Reviews: