8
10. INSTALLATION
NOTE: INSTALLATION AND REPAIR
SHOULD BE PERFORMED BY A
QUALIFIED SERVICE PERSON. THE
APPLIANCE SHOULD BE INSPECTED
BEFORE USE AND AT LEAST ANNUALLY
BY A PROFESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING MA Y BE
REQUIRED DUE TO EXCESSIVE LINT
FROM CARPETING, ETC. IT IS
IMPERATIVE THAT THE CONTROL
COMPARTMENT, BURNING AND
CIRCULATING AIR PASSAGEWAYS OF
THE APPLIANCE BE KEPT CLEAN.
Install the fireplace insert in the following order:
1. Make sure that the insert will fit into the fire
place. Most Zero Clearance wood fireplaces
will need to be modified. The refractory can be
removed if necessary and the front of the
appliance can be altered to allow the insert to
fit into the cavity. Holes will have to be made
in the firebox for the entry of gas and electrical
but the chamber must not be altered beyond
this.
2. Clean and inspect chimney.
3. Plan layout of gas line.
4. Plan layout of electrical.
5. Install the chimney liner as instructed in
SECTION 9.
6. Clean out and vacuum the solid fuel fireplace.
Make sure that the fireplace is completely
cool and has not been used for a few days.
7. Make sure that the solid fuel fireplace base is
level and if not make any necessary
adjustments.
8. Slide unit into place attaching draft hood and or
chimney liner as required.
9. Hook up gas line.
10. Hook up electrical.
11. Remove glass by removing two screws behind
upper grill and lifting door off bottom door
retainer (glass is very fragile).
12.
Log Installation:
- Remove logs from carton (4) and inspect.
- Install as per Log Placement set up.
- Purge lines and test pilot operation.
13.
Ember Kit Instructions:
Spread supplied rock evenly on the bottom
of the fireplace around the log set (DO NOT
PLACE ROCK ON BURNERS), next tear
ember wool into small thin pieces and place
evenly over front burner .
14. Re-install the glass door.
15. Check for correct operation
(See SECTION 12)
16. Install Surround and Grills as per
instructions.
17. Gas fired appliances may be used only for
supplemental heat and/or decorative
purposes and under no circumstances shall
they provide a primary heat source..
NOTE: DO NOT BLOCK THE SIDES OR
TOP OF THE APPLIANCE AS THIS WILL
AFFECT THE PROPER AND SAFE
OPERATION OF THE UNIT.