
ZCVRB47 –Vented Chase- Style 1 – OPENING WITH NO GRILL
Vertical Venting must use
Firestop Spacer (ZDVFS) or Attic
Insulation Shield and Sealant
SEALED ENCLOSURE
TOP VIEW
52”
MIN
70”
MIN
Open Area
Open
Area
VENTILATION PLATES MUST BE REMOVED
⚠
NOTE:
Minimum Opening is
105 sq. inches of free air
.
⚠
NOTE:
If using insulation in
vented chase (i.e. for outside wall),
wall board / drywall is required to
support all insulation.
Vented chase must be clean and
free of all debris (i.e. loose
insulation, pieces of wood, etc.).
⚠
NOTE:
HEAT CANNOT BE
DISCHARGED INTO THE
WALLS, FLOOR, OR CEILING.
Heat must exit through the required
vented chase opening near the
ceiling.
Exterior wall is insulated
and drywalled.
105 SQ. IN. MINIMUM
1-1/4” MIN with 3 Sides Open
105 SQ. IN.
MINIMUM
1-1/4” MIN with 3
Sides Open
105 Sq. In. MIN
47”
FRAMING I.D.
70”
MIN
38-3/4”
Ceiling / Enclosure Top
Open Area
Optional Attic
Insulation Shield
(ZDVAIS, ZDVAIS24)
70”
MIN
Ceiling / Enclosure Top
Open Area
21
Summary of Contents for marquis SERENE MQZCVRB47LPE2
Page 47: ...Gas Conversion for Modulator PART C 47...
Page 61: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 61...
Page 62: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 62...
Page 69: ...Proflame 2 Remote Control 69...
Page 71: ...71...