to permit the entrance of a 1/8-inch (3.2 mm) diameter
rod.
Cylinder valves shall be readily accessible for hand
operation. A door on the enclosure to gain access to the
cylinder valves is acceptable, provided it is non-locking
and can be opened without the use of tools.
There shall be a minimum clearance of 2 inches (50.8
mm) between the lower surface of the floor of the LP-gas
supply cylinder enclosure and the ground.
The design of the enclosure shall be such that (1) the LP-
gas supply cylinder(s) can be connected, disconnected
and the connections inspected and tested outside the
cylinder enclosure; and (2) those connections which
could be disturbed when installing the cylinder(s) in the
enclosure can be leak tested inside the enclosure.
Be certain to mount or set the LP-gas cylinder on a flat
stable surface and retain it to prevent it from tipping.
E. Purge the gas supply line of any trapped air prior to
the first firing of the unit.
WARNING: During the initial purging and
subsequent lightings, NEVER allow gas valve to
remain "OPEN" position without first placing a
burning match on the top of the burner.
F. Place the logs on the burner assembly. See log
placement instructions.
G. Test fire the unit after referring to the
SAFETY
INFORMATION and LIGHTING
INSTRUCTIONS
found in Section 13 of this
manual.
H.
Do not leave the burner on with the cover on.
Figure 1
GAS SPECIFICATIONS
FP2085N
FP2085LP
FP2785N
FP2785LP
Fuel
Natural Gas
Liquid Propane
Maximum Supply Pressure
10 IN. W.C./2.47 KPa
13 IN. W.C./3.24 KPa
I. If LP-Gas outdoor firepits are used continuously
after a couple of hours, you could see the possibility
of the flame decreasing in size. If this happens, turn
off the control valve and the tank valve and wait a
couple of hours before lighting again or switch
propane tanks. The propane tank is freezing up due
to the volume of gas being taken out of the tank.
Warning
DO NOT LEAVE FIREPIT
UNATTENDED WHEN IN USE
Summary of Contents for CR97-003